Owner`s manual
17
Champion Spas®
OWNER'S MANUAL
HEATING MODES
There are two Heating Modes, described as READY and REST.
READY Mode will allow the spa to “Poll” (circulating the water every 30 minutes to sense the
temperature) and determine a need for heat. The Panel will maintain a “current” temperature
display.
-READY Mode maintains a constant water temperature. It will circulate water every
30 minutes, heat as needed in order to maintain a constant set water temperature using
Pump 1 Low Speed and refresh the temperature display.
REST Mode will not “Poll” and will only heat during filter cycles. The panel will not display a
current temperature until Pump 1 has circulated for a minute or two.
-REST Mode will only allow heating during programmed filter cycles. In REST Mode
it won’t circulate every 30 minutes to sense the water temperature, so the temperature
display may not show a current temperature until the filtration pump has been running
for a minute or two.
Choosing Between Ready and Rest Mode
Press the TEMP button, then the LIGHT button repeatedly until MODE appears. Pressing the
TEMP button will toggle between SET READY and SET REST. Choose one, and then Press
LIGHT to set and exit.
If the filtration pump has been off for an hour or more, and when any function button (except
Light) is pressed on the panel, the pump used in conjunction with the heater will run so that the
temperature can be sensed and displayed.
In REST Mode the screen will display [RUN][PUMP][FOR][TEMP] if the filtration pump has
not run for over 1 hour.