• Install at least 5 feet (1.5 m) from all metal surfaces. A spa may be installed within 5 feet
of a metal surface if each metal surface is permanently connected by a minimum No. 8
AWG (8.4 mm) solid copper conductor attached to the wire ground connector on the
terminal box that is provided for this purpose if in accordance with National Electrical
Code ANSI/NMFPA70-1993.
• Install your spa in such a way that drainage is away from the electrical compartment
and from all electrical components.
AVOIDING RISK OF INJURY
To reduce the risk of injury to persons, DO NOT remove suction fittings located at
the bottom footwell of the spa.
• The suction fittings in the spa are sized to match the specific water flow created by the
pump. Never replace a suction fitting with one rated less than the flow rate marked on
the original suction fitting. Never operate the spa if the suction fittings are broken or
missing.
• There is a danger of slipping and falling. Remember that wet surfaces can be very
slippery. Take care when entering or exiting the spa.
• People with infectious diseases should not use the spa.
• Keep any loose articles of clothing or hanging jewelry away from rotating jets or other
moving components.
The use of drugs, alcohol, or medication before or during spa use may lead to
unconsciousness with the possibility of drowning.
Persons using medications should consult a physician before using a spa; some medication
may cause a user to become drowsy, while other medication may affect heart rate, blood
pressure, and circulation.
• Persons taking medications which induce drowsiness, such as tranquilizers,
antihistamines or anticoagulants should not use the spa.
• Water temperature in excess of 104ºF (38ºC) may be injurious to your health.
• Pregnant women should consult a physician before using spa.
• Persons suffering from obesity, or with a medical history of heart disease, low or high
blood pressure, circulatory system problems, or diabetes should consult a physician
before using spa.
• Persons using or having Implanted Pacemakers or Defibrillators should consult their
physician prior to using a spa, as there are risks of electrocution.
UNCLEAN WATER
Keep the water clean and sanitized with correct chemical care.
• Maintain water chemistry in accordance with chemical manufacturer’s instructions.
Important:
Turn the Jet Pump on high speed and it will operate for a 15 minute cycle after adding ANY
spa water chemicals into the spa.
Clean the filter cartridges monthly to remove debris and mineral buildup which may
affect the performance of the jets, limit the flow, or cause a high limit problem.
!
!