Model: __________________________________________________________ Serial Number: ___________________________________________________ Date Installed: ____________________________________________________ Dealer: _________________________________ __________________________________________________________ Address: ______________________________________ _________________________________________________________ Telephone: _________________________________________ __________________________________________________
Tabl e o f Co n te n ts S pa C a r e a n d Water M a i n ten a n ce C ha mpion S AF ET Y I nstru ct i o ns Avoiding Risk to Children . . . . . . . . . . . . . . . . . . . . Avoiding Risk of Electrical Shock . . . . . . . . . . . . . . . Avoiding Risk of Injury . . . . . . . . . . . . . . . . . . . . . . Unclean Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Avoiding Risk of Hyperthermia . . . . . . . .
Champion Spas® SAFETY INSTRUCTIONS Read And Follow All Instructions AVOIDING THE RISK TO CHILDREN Risk of Child Drow ni ng Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use a spa unless they are supervised at all times. Warning: • To reduce the risk of injury, do not permit children to use this spa unless they are closely supervised at all times.
AVOIDING RISK OF INJURY • To reduce the risk of injury to persons, DO NOT remove suction fittings located at the bottom footwell of the spa. • The suction fittings in the spa are sized to match the specific water flow created by the pump. Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting. Never operate the spa if the suction fittings are broken or missing. • There is a danger of slipping and falling.
AVOIDING RISK OF HYPerTHERMIA The causes, symptoms and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6ºF. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting. The effects of hyperthermia include: 1. Failure to perceive heat. 2. Failure to recognize the need to exit the spa or hot tub. 3.
Important: The following contains important spa information, and we strongly encourage you to read and apply them. IMPORTAN T DO 'S & DON'TS Do: • Make sure you always lock the child resistant spa cover locks after using the spa for your children’s safety. Every Champion Spas® is equipped with a locking cover that meets the ASTM F1346-91 Standard for Safety Covers. • Test the water temperature with your hand before allowing children to enter the spa to be sure that it’s comfortable.
SPA SP E CI F I CAT ION S Width Length Height Average Fill Dry Weight Average Seating Fill Weight Locations 108 78.5” 2m Round Round 31.5” 0.80 m 240 gal 909 L 310 lbs. 175 kg 2,278lbs. 743 kg 3 213 59” 1.49 m 82” 2.08 m 29” 0.74 m 150 gal 568 L 300 lbs. 136 kg 1,500 lbs. 680 kg 2 215 57" 1.45 m 80" 2.03 m 29" 0.74 m 150 gal 568 L 385 lbs. 175 kg 1650 lbs 748 kg 2 320 67” 1.70 m 80” 2.03 m 32” 0.80 m 240 gal 909 L 480 lbs.
IN S TALLATION INS T RU CT IONS Location Preparation Your Champion Spas® model is totally self-contained and portable. You can install the spa outside or inside. Preferable places are on a patio, deck or indoors. The spa should always be placed on a structurally strong, level surface. Other items you need to consider are the following: • Verify that the location chosen can support the weight of the spa, the water of the spa and its occupants.
E L E C T RI C AL REQUIREMENT S AND PRECAU TIONS Your Champion Spas® model has gone through numerous tests to verify that all of the spa functions operate. Beyond the tests, your Champion Spas® model has been designed to provide the maximum safety against electrical shock. Read and follow the electrical installation requirements and instructions completely. The next few pages will assist you in properly connecting the electrical input. Follow the electrical instructions for your specific spa model.
Factory Installed Neutral (Pigtail) Incoming Ground (Green) Incoming Power (Black) boT To m V i EW o F b rEa K Er Power to Spa Neutral to Spa Ground to Spa Outgoing Power to Spa Outgoing Neutral to Spa Incoming Power (Black or Red) Incoming Neutral (White) Electrical Spa Wiring Connection instructions important: Never, under any circumstances, should you connect power to the neutral terminal . terminal . 1 . Identify the TB1 terminal block, located inside the spa power pack on the left side . 2 .
110 / 2 2 0 Vo lT Con VErT ibl E modElS • 108* • 213* • 215* • 320* 1 10 VolT ElECTriCa l r Eq u i r EmEnTS : *The above models are manufactured with the Champion Spas® 110V/220V convertible spa pack . The unit is factory wired for 220 Volt applications with 4 kW heater operation . The model can be converted for 110 Volt applications and to run with a 1 kW heater operation . The 110 Volt model must be connected to a “dedicated” 110 Volt 20Amp grounded circuit .
Installation I nstru ct i o ns : The following instructions are for the conversion of the Champion Spas® models 110V/220V control pack from a 220 Volt application to a 110 Volt application. Important: Use only approved pressure-type wire splicing lugs or connectors suitable for the size and type of wiring used. Before servicing the spa, make sure all power to the spa is disconnected. Follow these instructions for a successful electrical installation. 1. Unscrew the screws on the front access panel. 2.
INI T IAL OP ERAT ING INS TRU CTIONS Start-Up and Refill Procedures Your Champion Spas® model has been tested at the manufacturing plant to ensure that all of the spa functions operate. During the test procedure, a small amount of water may have remained in the spa plumbing. Through the shipping process water may have spotted the spa shell. You may need to wipe down the shell with a soft cloth. Please read and follow the start-up instructions to ensure a successful start-up or refill.
Start-up Procedures 1. For a successful start-up, remove both filter cartridges, and fill the spa with water through the openings in the filter compartment. a. b. c. d. e. Locate the filter compartment area. Pull up and remove filter cover. Remove each filter cartridge and screen adapter by turning counter clockwise. After removing the filter cartridges and screen adapters, place a garden hose through one of the filter openings.
E QUIPM EN T MAINTENANCE Replacing the Spa’s Light Bulb The spa’s light bulb is located inside the equipment compartment. Remove the front access panel, by first removing the screws on the access panel. Then locate the light housing mounted to the spa shell. Grasp the bulb holder on the back of the light niche. Turn bulb holder counter clockwise to release it from the light niche. Pull bulb out of receptacle and replace it with a new light bulb, available at your Champion Spas® dealer.
Operating the Hydro Pump s Jets Button Activates the hydro jet pump(s) for maximum hydrotherapy jet action. Press the Jets button once for low speed, twice for high speed and a third time to turn the pump off. If your spa has a two pump system there will be a one speed pump and a two speed pump. For the one speed pump press the Jets button once for high speed and again to turn the pump off. When the pump(s) are activated the indicator below the Jets button will light up.
Heating MODEs The heat mode on the Champion Spas® models are programmed to maintain the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes. "St" will be displayed momentarily when you are in Standard Mode. Preset Filter Cycle The first filter cycle begins 6 minutes after the spa is powered up. The second filter cycle begins 12 hours later.
d iag n o sti c mess ages C h am p ion S p as ® OWN E R' S M AN UAL 17
S pa C a r e a n d wate r Ma in tenance General Information Champion Spas® are manufactured from the highest quality, most durable materials available today. We recommend that a spa maintenance program be followed. The care you take will ultimately determine how long your spa or its individual components will last. This section will help you maintain your investment.
Filter System Champion Spas® are equipped with two standard filter cartridges. As with any filtering system, the filter cartridges may become clogged with particles, body oils or calcification resulting in poor water quality and reduced water flow. It is important to maintain a clean, unobstructed filtering system. A reduced water flow may cause a failure of the filter cycles to operate due to the pump shutting down.
3. To reinstall the spa pillow, carefully bend the pillow slightly to allow the slit on the back of the pillow to slip over the attachment bar retainer on the spa shell. 4. After the pillow slips over the attachment, press the pillow down into the recess in the spa shell. Important: Just pulling the pillow straight up and off of the attachment bar will eventually damage the pillow. This abuse is not covered under warranty.
Important reminders: • Do unlock and release all cover locks before attempting to open cover. • Do remove snow buildup to avoid damage of the foam core from the additional weight of the snow (not covered under warranty). • Do lock cover lock straps to secure the cover when the spa is not in use. • Do not drag or lift the spa cover using either the flaps, or the cover tie downs. • Do not walk, stand, or sit on the cover.
11. Place the vacuum hose down the filter cartridge openings and vacuum any water from filter compartment. 12. With a Shop Vac, go to every jet in the spa (including suction fittings) and place vac hose over the face of every jet and vacuum out any water left in the lines. Do the same to the filter housing and filter cartridge openings. Continue to do the same to the heater and the plumbing going into the pump(s). Remove every jet valve assembly and continue to vacuum out any water in the plumbing lines.
Water Q ual ity Ma in te n ance General Information As the owner of a Champion Spas®, endless hours of entertainment, recreation, and relaxation await you. Caring for your spa will become a routine and pleasant part of your daily activities. You will be able to maintain your spa water and keep your spa equipment in excellent condition. To do so you first must balance your spa’s water. Balanced Water Balanced water ensures spa bathers safety as well as protecting the spa heater and components from corrosion.
Example: At low total alkalinity levels, the water’s pH easily drifts, making frequent pH adjustments necessary and the added expense of multiple chemical treatments . On the other hand, a high total alkalinity level keeps the water pH rigidly fixed . If pH adjustment is necessary, you will need unusually large amounts of treatment chemicals to change the water’s pH. Recommended Range: 80 to 120 Parts Per Million (PPM) potential problems: 1 . pH difficult to maintain .
Example: At low total alkalinity levels, the water’s pH easily drifts, making frequent pH adjustments necessary and the added expense of multiple chemical treatments. On the other hand, a high total alkalinity level keeps the water pH rigidly fixed. If pH adjustment is necessary, you will need unusually large amounts of treatment chemicals to change the water’s pH. Recommended Range: 80 to 120 Parts Per Million (PPM) Potential Problems: 1. pH difficult to maintain.
Shock Treatment with Granular Disinfectant Adding granular chlorine or bromine disinfectant to the water in amounts much larger than normal is called “shocking” the spa and should not be confused with non-chlorine shock. An occasional shock treatment destroys algae, bacteria, and chloramines. After shocking your spa, do not allow bathers to enter the spa until disinfectant levels drop to normal. What Causes Loss of Disinfectant? • Algae: The presence of algae will consume large amounts of disinfectant.
o p Er aTionS Troubl E Sh ooT i ng g u i dE p roblE m proba b l E Cau S E S o l u Ti o n S Spa is not • Power failure • Check power source operating • GFCI breaker tripped • Try resetting GFCI breaker. If breaker continues to trip, contact your dealer.
opEr aTio n S Tro ub l E S h ooTi n g g u i d E pro blEm p robablE C auSE S o l uTio nS Spa jets/ • Normal power filtration cycle • No action necessary pump(s) • "Ice Mode" • No action necessary • Panel may have malfunctioned • Contact your dealer Water does • Bad water chemistry • Balance water not clear up • Dirty filter cartridges • Clean or replace filters • Ozone generator not operating • Locate ozone generator, a purpler turn on automatically Not able to operate main control panel
S e rv i ce a nd Wa r r a nty Informati on General Service Information Champion Spas® models have been designed to provide years of trouble-free use. As with any appliance, problems may occasionally occur that require the expertise of a qualified service person. Though such simple repairs as resetting a GFCI switch or breaker, resetting a high limit thermostat or replacing a light bulb may not require a service call, they may indicate that a more serious condition exists.
30 C h ampi o n Spa s® OWNER 'S M A N UA L and Cle an S eou s cel lan Mis Ser v ic e pa She Spr ll ay Cle an Filt er Ca rtr idg Soa e kF ilte rC art r id ge Co mp lete Spa Wa ter Bal Cle anc an e and Co ndi tio nV iny Wi l Sp nte aC rize ove Spa r Dr ain DA TE S pa C a r e A nd Mainte nan ce Record
and Cle an S eou s cel lan Mis Ser v ic e pa She Spr ll ay Cle an Filt er Ca rtr idg Soa e kF ilte rC art r id ge Co mp lete Spa Wa ter Bal Cle anc an e and Co ndi tio nV iny Wi l Sp nte aC rize ove Spa r Dr ain DA TE S pa C a re An d Mainte nance Record C h am p ion S p as ® OWN E R' S M AN UAL 31
32 C h ampi o n Spa s® OWNER 'S M A N UA L and Cle an S eou s cel lan Mis Ser v ic e pa She Spr ll ay Cle an Filt er Ca rtr idg Soa e kF ilte rC art r id ge Co mp lete Spa Wa ter Bal Cle anc an e and Co ndi tio nV iny Wi l Sp nte aC rize ove Spa r Dr ain DA TE S pa C a r e A nd Mainte nan ce Record
33 Wade Road Latham, NY 12110 518-786-1200 fax: 518-782-0632 www.championspas.