Owner`s manual
9
Champion Spas®
OWNER'S MANUAL
Electrical Spa Wiring Connection
I
nstructions
II
mportant:mportant:
Never, under any circumstances, should you connect power to the neutral terminalNever, under any circumstances, should you connect power to the neutral terminal
..
1
.
Identify the TB1 terminal block, located inside the spa power pack on the left side
.
2
.
Connect the 8 AWG, WHITE wire, from the GFCI 50 amp breaker,to the WHITE "NEU"
terminal on TB1
.
3.
Connect the 8 AWG, BLACK wire, from the GFCI 50 amp breaker, to the BLACK "HOT"
terminal on TB1
.
4
.
Connect the 8 AWG, RED wire, from the GFCI 50 amp breaker, to the RED "HOT"
terminal on TB1
.
5
.
Connect the 8 AWG, GREEN wire, from the GFCI 50 amp breaker, to the GREEN
"GROUND" location on the "BONDING LUGS" terminal
.
6
.
At least two additional lugs marked “BONDING LUGS” are provided on the external surface
of one of the bonded components metal enclosures
.
To reduce the risk of electrical shock,
connect the local common bonding grid in the area of the hot tub or spa to these terminals
with an insulated or bare copper conductor not smaller than No
.
6 AWG
.
7
.
All field-installed metal components such as rail, ladders, drains or other similar hardware
within 10 ft (3m) of the spa or hot tub shall be bonded to the equipment grounding bus with
copper conductors not smaller than No
.
6 AWG
.
8
.
Replace the control box cover and securely tighten the fastening screws
.
Close and secure the
equipment compartment panel
.
Note:
Always use copper wire only (3 wire with ground; 8 gauge under 50ft, 6 gauge over 50ft)
The electrical supply for this product must include a suitable rated switch or circuit breaker
to open all ungrounded supply conductors to comply with Section 422
.
20 of the National
Electrical Code ANSI/NEPA 70-1987
.
The disconnecting means must be readily accessible to
the tub occupant but installed at least 5 feet (1.5m) from tub water
II
mportant:mportant:
Please review the back of the spa pack cover, located in the spa equipment bay, for a complete Please review the back of the spa pack cover, located in the spa equipment bay, for a complete
spa equipment wiring diagramspa equipment wiring diagram
..
Power
Power
Power
to
Spa
Neutral
Neutral
Neutral
to
Spa
Factory
Factory
Factory
Installed
Installed
Installed
Neutral
Neutral
Neutral
(Pigtail)
(Pigtail)
(Pigtail)
Ground
to
Spa
Outgoing
Power
to
Spa
Spa
Spa
Outgoing
Neutral
to
Spa
Incoming
Power
(Black
or
Red)
Incoming
Incoming
Neutral
(White)
(White)
(White)
Incoming
Incoming
Incoming
Power
Power
Power
(Black
)
Incoming
Incoming
Incoming
Ground
Ground
Ground
(Green)
BOTTOM VIEW
OF B R E A KER