INSTALLATION INSTRUCTIONS:
The following instructions are for the conversion of the Champion SpasĀ® models 110V/220V
control pack from a 220 Volt application to a 110 Volt application.
Important:
Use only approved pressure-type wire splicing lugs or connectors suitable for the size and type of
wiring used.
Before servicing the spa, make sure all power to the spa is disconnected. Follow these instructions
for a successful electrical installation.
1. Unscrew the screws on the front access panel.
2. Carefully pull access panel toward you (away from spa) and pull upward. Set access
panel aside.
3. Locate the spa power pack. Loosen the screws on the front of the control box. Remove the
control box cover and the terminal block will be exposed.
4. Route the GFCI power cord through the vent hole in the base of the equipment
compartment and out from under the corner of the spa.
Note: 110 Volt installations require a 60Hz, single phase, two-wire electrical service plus
ground (Line 1, Neutral and Ground) and must be connected using a minimum supply
conductor ampacity of 20 Amps and a minimum GFCI circuit breaker size of 20Amps.
5. Input the GFCI power cord to the terminal block inside the spa pack.
6. Connect the 8 AWG WHITE wire, from the power cord, to the WHITE "NEU" terminal
on TB1.
7. Connect the 8 AWG BLACK wire, from the power cord, to the BLACK "HOT" terminal on
TB1.
8. Connect the 8 AWG GREEN wire, from the power cord, to the GREEN "GROUND"
location on the "BONDING LUGS" terminal.
9. Connect jumper wire (jumper wire taped to the back of the spa pack) to J11 and J32.
10. Move dip switch #10 to the ON position.
11. Replace the control box cover and securely tighten the fastening screws. Close and secure the
equipment compartment panel.
Note: Please review the back of the spa power pack cover, in the equipment bay, for a complete
spa wiring diagram.