P/N 114958 - Condensate Removal Option Installation Instructions
Utility Connections for the DH5000 with Condensate Removal Option
Plumbing Connections
! VERY IMPORTANT !
The incoming cold water supply pressure must be a minimum
of 45 PSI flowing pressure measured at the cold water supply connection.
1. The DH5000 dishwasher equipped with a Condensate Removal Option requires an
incoming cold water supply only (See Figure E below).
COLD WATER — 3/4" NPT, 55-75°F/13-24°C Maximum temperature, with a minimum
incoming flowing pressure of 45 PSI measured at the dishwasher supply connection
before adjusting operating pressure to 20/25 PSI flowing pressure.
2. A water hardness of 3 grains/gal (US) [51.3 mg/L] or less is recommended.
The cold water supply connection is located on the left side of the dishwasher
approximately 64" above the finished floor (see the illustration below).
3. A manual shut-off valve, 3/4" or larger, should be installed in the cold water supply line
as close to the dishwasher as possible for servicing.
E
3/4" NPT
Cold water
supply connection
Detail View
64"
[1626]