82
The Direct Vent Fan Electrical Control Box is shipped
prewired to the dishwasher and stowed in the left rear
corner of the machine. Mounting holes and fasteners
are provided to mount the control box on the left side
of the machine. A 12 ft. [3.7m] vent fan cable is
prewired to the control box. (See Figure G).
To Install the Electrical Control Box:
P/N 114959 - Direct Vent Option Installation Instructions
Installing the Direct Vent Fan Electrical Control Box on the left-hand side
of the DH5000
1. The electrical control box must be installed
before the dishwasher is permanently
placed and before the dishwasher tables
are connected to the dishwasher.
2. Refer to Figure G at right. The photo
shows the electrical control box mounted
on the left side of the dishwasher
approximately 46" [1.2 m] above the
finished floor.
3. Note the 12 ft. [3.7 m] vent fan power
cable for the Champion supplied vent fan
has been prewired to the control box.
This cable is provided to connect 120VAC
power to the vent fan.
4. Refer to Figure H at right. The photo
shows the storage location for the
electrical control box during shipping.
5. Carefully lift the control box and mounting
bracket assembly from the rear of the
dishwasher and place it on the floor on
the left-hand side of the machine.
6. Locate the (4) 1/4-20 x 1/2" Hex Head
G
CONTROL
BOX
VENT FAN
CABLE
H
CONTROL
BOX
! ATTENTION !
The Direct Vent Fan Control box can be wall-mounted using a Wall Mount Kit, P/N 900958.