Specifications

4 ζ
ZETA6104 Installation Guide
Pre-installation Adjustments
Factory Settings May Be Sufficient (if so, skip this section)
Zeta motors are pre-configured for series operation
Motor current is factory set for the Zeta motor if it was ordered with the ZETA6104
Device address is set to zero (if daisy-chaining you can automatically establish with the ADDR command)
Serial communication method is RS-232C
Selecting Series or Parallel Motor Wiring
ZETA83–135
Speed-RPS
0
Torque
100
200
300
400
500
oz-in
(0.70)
(1.40)
(2.10)
(2.80)
(3.50)
(N-m) watts
(hp)
193 Series
(0.26)
355 Parallel
(0.48)
Power
0
10
20 30 40 50
Series
Parallel
ZETA57–51
Speed-RPS
0
Torque
15
30
45
60
75
oz-in
(0.11)
(0.21)
(0.32)
(0.42)
(0.53)
(N-m) watts
(hp)
60 Series
(0.08)
129 Parallel
(0.18)
Power
0
10
20 30 40 50
Series
Parallel
ZETA83–93
Speed-RPS
0
Torque
80
160
240
320
400
oz-in
(0.56)
(1.12)
(1.68)
(2.24)
(2.80)
(N-m) watts
(hp)
180 Series
(0.24)
350 Parallel
(0.47)
Power
0
10
20 30 40 50
Series
Parallel
ZETA83–62
Speed-RPS
0
Torque
40
80
120
160
200
oz-in
(0.28)
(0.56)
(0.84)
(1.12)
(1.40)
(N-m) watts
(hp)
120 Series
(0.16)
260 Parallel
(0.35)
Power
0
10
20 30 40 50
Series
Parallel
ZETA57–102
Speed-RPS
0
Torque
30
60
90
120
150
oz-in
(0.21)
(0.42)
(0.63)
(0.84)
(1.05)
(N-m) watts
(hp)
80 Series
(0.11)
= Torque
= Power
186 Parallel
(0.25)
Power
0
10
20 30 40 50
Series
Parallel
ZETA57–83
Speed-RPS
0
Torque
25
50
75
100
125
oz-in
(0.18)
(0.35)
(0.53)
(0.70)
(0.88)
(N-m) watts
(hp)
80 Series
(0.11)
175 Parallel
(.23)
Power
0
10
20 30 40 50
Series
Parallel
Z
eta Motor Curves
Use series wiring if your application permits. The ZETA motor
comes from the factory with a permanently attached motor cable. The connector on
the cable is prewired for series motor current (see drawing below). The operating
temperature of a motor connected in series will be lower than that of a motor
connected in parallel. Typically, series connections work well in high torque/low
speed applications.
ZETA Motor
CONNECTOR
INTERLOCK
A
CENTER TAP
A+
A–
EARTH
B+
B–
B
CENTER TAP
INTERLOCK
Shield is internally connected to the motor’s case.
Do not lengthen or remove this jumper.
PM
Phase A
Windings
Phase B
Windings
Red
Blue
Black
Yellow
White
Brown
Green
Orange
Shield
When to use parallel wiring. At higher speeds, a motor connected in
parallel will produce more torque than the same motor connected in series. Use
caution, however, because the operating temperature of the motor in parallel will
be much hotter. If you operate your motor in parallel, measure motor temperature
under actual operating conditions. If the motor exceeds its maximum case
temperature, reduce the duty cycle to limit motor heating. ZETA motors have
maximum case temperatures of 212°F (100°C).
To rewire the motor connector for parallel motor current, pull back the rubber boot
that covers the connector and attach wires from the motor cable as shown below.
Shield is internally connected to the motor’s case.
Do not lengthen or remove this jumper.
ZETA Motor
CONNECTOR
INTERLOCK
A
CENTER TAP
A+
A–
EARTH
B+
B–
B
CENTER TAP
INTERLOCK
PM
Phase A
Windings
Phase B
Windings
Red
Blue
Black
Yellow
White
Brown
Green
Orange
Shield
Non-Compumotor Motors: If you are using a non-Compumotor motor, refer
to Appendix B for connection instructions and current-select DIP switch settings.