Specifications
Chapter 1. Installation
5
DIP Switch Settings – Motor Current, Address, Autobaud
CAUTION
Do not set switches 6-11 to ON at the
same time. This invokes a factory test
mode in which the ZETA6104 executes
a motion sequence upon power up.
0.14 off off off off off
0.26 off off off off on
0.39 off off off on off
0.51 off off off on on
0.64 off off on off off
0.76 off off on off on
0.89 off off on on off
1.01 off off on on on
1.14 off on off off off
1.26 off on off off on
1.38 off on off on off
1.51 off on off on on
1.63 off on on off off
1.76 off on on off on
1.88 off on on on off
2.01 off on on on on
2.14 on off off off off
2.26 on off off off on
2.38 on off off on off
2.51 on off off on on
2.63 on off on off off
2.76 on off on off on
2.88 on off on on off
3.01 on off on on on
3.13 on on off off off
3.26 on on off off on
3.38 on on off on off
3.50 on on off on on
3.63 on on on off off
3.75 on on on off on
3.88 on on on on off
4.00 on on on on on
off off off off off 0 (default)
off off off off on 1
off off off on off 2
off off off on on 3
off off on off off 4
off off on off on 5
off off on on off 6
off off on on on 7
off on off off off 8
off on off off on 9
off on off on off 10
off on off on on 11
off on on off off 12
off on on off on 13
off on on on off 14
off on on on on 15
on off off off off 16
on off off off on 17
on off off on off 18
on off off on on 19
on off on off off 20
on off on off on 21
on off on on off 22
on off on on on 23
on on off off off 24
on on off off on 25
on on off on off 26
on on off on on 27
on on on off off 28
on on on off on 29
on on on on off 30
on on on on on 31
Factory Settings: If you ordered the Zeta motor
as part of your ZETA6104 system
(e.g., ZETA6104-83-62), then the DIP switches will
be factory-configured to operate your motor in a
series wiring configuration.
If you ordered the ZETA6104 without a motor, all
DIP switches are factory-set to the OFF position.
= off = on
off
Move the
Cover
Top View of ZETA6104
12345 12
Motor Current (Amps)
Zeta57-51
Series
Zeta57-83
Series
Zeta57-102
Series
Zeta83-62
Series
Zeta57-51
Parallel
Zeta83-93
Series
Zeta57-83
Parallel
Zeta57-102
Parallel
Zeta83-135
Series
Zeta83-xx
Parallel
AutoBaud
Address
on off
If your terminal is not capable of 9600 baud, use this procedure
to automatically match your terminal's speed of 1200, 2400, or
4800 baud.
1. Set switch 6 to on and switch 7 to off.
2. Connect the ZETA6104 to the terminal.
3. Power up the terminal.
4. Cycle power to the ZETA6104 and immediately press the
space bar several times.
5. The ZETA6104 should send a message with the baud rate
on the first line of the response. If no baud rate message is
displayed, verify steps 1-3 and repeat step 4.
6. Change switches 6 & 7 to off.
7. Cycle power to the ZETA6104. This stores the baud rate
in non-volatile memory.
6 7 8 9 10 11
Automatic Addressing:
If you are connecting multiple
units (see page 9), you can
use the ADDR command to
establish a unique address for
each unit. The ADDR
command overrides the DIP
switch setting. For details,
refer to the
6000 Series
Software Reference Guide
or
the
6000 Series Programmer's
Guide
.
NOTE: Autobaud works only on the COM 1 serial port.