All other brand or product names which may be mentioned in this manual are trademarks or registered trademarks of their respective companies or organizations. The information furnished in this manual is for informational use only and is subject to change without notice. Please check www.vari-lite.com for latest version. Philips Vari-Lite assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual.
FOREWORD How To Obtain Warranty Service A copy of the Philips Vari-Lite Limited Warranty was included in the shipping package for this VARI❋LITE product. To obtain warranty service, please contact customer service at 1-877-VARI-LITE (1-877-827-4548), +1-214-647-7880, or entertainment.service@philips.com and request a Return Material Authorization (RMA) for warranty service.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Compliance Notice FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment.
FOREWORD Safety Notice It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation before installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product. Safety symbols used throughout this manual are as follows: CAUTION advising of potential damage to product. WARNING advising of potential injury or death to persons.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXCESSIVE EXPOSURE TO UV RADIATION 1. Many VARI❋LITE luminaires use a lamp that produces UV radiation. DO NOT look directly at lamp. 2. It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired. For example, by cracks or deep scratches.
FOREWORD Sicherheitshinweise Es ist äußerst wichtig, ALLE Sicherheitsinformationen und -hinweise in diesem Handbuch und dem beiliegenden Informationsmaterial zu lesen, bevor Sie die hierin beschriebenen Produkte installieren bzw. bedienen. Halten Sie bei der Installation und dem Einsatz dieses Produkts alle Warnhinweise und Vorsichtsmaßnahmen ein. Folgende Sicherheitssymbole werden in diesem Handbuch verwendet: VORSICHT - weist auf möglichen Produktschaden hin.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL WARNUNG: HINWEISE ZUM SCHUTZ GEGEN ÜBERHÖHTE UV-STRAHLUNG 1. Viele VARI❋LITE -Scheinwerfer verwenden die Lampentyp, der UV-Strahlen abgibt. SCHAUEN SIE NICHT direkt in die Lampe. 2. Es ist gefährlich, Leuchten ohne Linsen oder Blenden zu bedienen. Blenden, Linsen oder Ultraviolettschirme müssen ausgetauscht werden, sofern deren Schutzwirkung durch sichtbare Beschädigung (z. B. Sprünge oder Schrammen) eingeschränkt ist.
FOREWORD Notes de sécurité Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE UNE EXPOSITION EXCESSIVE AUX RAYONS UV 1. Plusieurs luminaires VARI❋LITE utilisent une lampe qui produit des rayons UV. NE PAS fixer son regard sur la lampe. 2. L’utilisation des luminaires sans lentille ou blindage pose des risques.
FOREWORD Aviso sobre Seguridad Es muy importante leer TODA la información e instrucciones sobre seguridad que se indica en este manual así como en los documentos adjuntos antes de instalar y operar los productos descritos. Se debe prestar atención a todos los avisos y advertencias durante la instalación y uso de este producto. Los símbolos de seguridad usados en este manual son los siguientes: CUIDADO, indica posibles daños al producto. ADVERTENCIA, indica posibles lesiones o muerte a las personas.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL ADVERTENCIA: INSTRUCCIONES PARA PROTECCIÓN CONTINUA CONTRA LA EXPOSICIÓN EXCESIVA DE RADIACIÓN ULTRA VIOLETA 1. Muchas luminarias VARI❋LITE usan un tipo de lámpara que produce radiación UV. NO mire directamente a la lámpara. 2. Es peligroso operar luminarias sin lentes o protectores. Debe cambiar los protectores, lentes o pantallas ultravioletas si se aprecia que han sido dañadas, y que su efectividad pudiera estar deteriorada.
FOREWORD 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL xii 2 7 Au gu st 2 013 02 .9 679 .
TABLE OF CONTENTS Introduction About This Manual ...................................................................................................... Additional Documentation........................................................................................... Text Conventions ......................................................................................................... Customer Service........................................................................................................
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Gobo Wheel 3 ..................................................................................................... Index/Rotation..................................................................................................... VL3015 Spot Luminaire Timing VL3015 Spot Timing Channel Information............................................................... VL3515 Spot DMX Channels VL3515 Spot Channel Mapping..........................................
TABLE OF CONTENTS Heat ..................................................................................................................... Lamp Life............................................................................................................ Solid State Electronics ............................................................................................... Electrostatic Discharge (ESD) ............................................................................
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL xvi 2 7 Au gu st 2 013 02 .9 679 .
INTRODUCTION : ABOUT THIS MANUAL Introduction About This Manual This manual provides necessary information regarding safety, installation, operation and routine maintenance for VARI❋LITE VL3015 / VL3515 Spot Luminaires. Familiarizing yourself with this information will help you to get the most out of your luminaire. WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential injury to yourself or others.
VARI❋LITE® - VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Text Conventions The following styles and meanings are used throughout this manual: Style Meaning [Button] Front panel button. Example: Press [Menu]. [Up] / [Down] arrows Press either [Up] or [Down] arrow button at Menu Display. MENU LCD Menu Display read-out. Example: Press [Up] / [Down] arrows until LAMP appears. Customer Service Our Goal At Philips Vari-Lite, we are committed to providing you the highest quality in customer service.
CHAPTER 1. Description This chapter contains descriptions of luminaire features and components, along with a list of accessories which are available. • Features • Components 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Features VL3015 Spot Standard Features The VL3015 Spot Luminaire has the following standard features: • 6:1 zoom optics system with 10° to 60° range. • CYM color mixing system. • Fixed, rotating color wheel with six interchangeable color filters. • Variable CTO color correction. • Mechanical iris provides continuous beam size control. • Three gobo/effects wheels combine to provide 14 rotatable, indexable gobo positions.
DESCRIPTION : FEATURES 1 VL3515 Spot Standard Features The VL3515 Spot Luminaire has the following standard features: • Shutter assembly with four blades: +/- 50° system rotation and +/- 30° blade rotation. • 6:1 zoom optics system with 10° to 60° range. • CYM color mixing system. • Fixed, rotating color wheel with six interchangeable color filters. • Variable CTO color correction. • One gobo/effects wheel provides five rotatable, indexable gobo positions and one open position.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Components Included Items The following illustration shows all items included with the luminaire: VL3015 / VL3515 Spot Luminaire Documentation CD ROM Product Registration Product Support Sheet VL3015 or VL3515 Spot Luminaire Unpack & Quick Start Guide Warranty Card 1500 Watt Short Arc Double-Ended Lamp* Neutrik PowerCon® AC Input Connector Note: *DO NOT handle arc lamp with bare hands. Wear cotton gloves. Keep lamp dirt and grease free.
DESCRIPTION : COMPONENTS 1 Replacement Items/Accessories The following optional and/or replacement items can be ordered directly from Philips Vari-Lite. (Please order by Philips Vari-Lite part number.) 02.96 79.000 2 A Philips Vari-Lite Part Number Accessory Description 22.9620.0194 Safety Cable Assembly 25.9661.0057 DMX Termination Connector Assembly 28.8500.0054 USB Luminaire Programming Kit 55.6840.0001 Truss Hook, Mega-Clamp, Round and Square 55.6841.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Luminaire Overview The following illustration shows the external luminaire components and controls. Head Assembly Houses color, gobo, strobe, zoom lens and iris or shutter mechanisms*. Also, the alternative reflector (Flat Field) is stored under the bottom head cover. (*dependant on luminaire model). Backcap Assembly Provides access to lamp for replacement and provides controls for beam adjustment.
CHAPTER 2. Installation This chapter contains instructions for installation of the luminaire. It includes connecting power and data, along with instructions for powering up the luminaire for the first time and addressing it within your system. • Power and Data Cabling Requirements • Installation Procedures • Powering Up • Addressing 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Power and Data Cabling Requirements Power The luminaire requires standard AC power distribution from 200-240 VAC, 50/60 Hz. Current required is 8 to 12 Amps depending on the AC supply voltage and product model. Note: The mating Neutrik PowerCon connector is supplied, however, you will need to purchase or construct a cable appropriate for your application.
INSTALLATION : POWER AND DATA CABLING REQUIREMENTS 2 For single-phase power at 200-240 volts RMS: Connection Pin AC Neutral X AC Line Y Ground (Earth) G X G Y For three-phase power at 208 volts RMS: Connection Pin Phase 1 X Phase 2 Y Ground (Earth) G X G Y WARNING: It is not recommended to power any VARI❋LITE luminaire from a dimmer - even in 'NONDIM' mode. Dimmer and non-dim modules are not suitable sources of power because their output modifies the AC wave form.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Data Cables The VL3015 / VL3515 Spot Luminaire is equipped with two, 5-pin XLR connectors for DATA IN and DATA THRU (out) applications. DATA IN requires a 5-pin, female XLR connector and DATA THRU requires a 5-pin, male XLR connector. When purchasing or constructing data cables, it is important that not only the correct cable type be used, but also quality cable to ensure a reliable DMX512 system.
2 INSTALLATION : POWER AND DATA CABLING REQUIREMENTS Recommended Cable Types/Manufacturers These are only a few of the suitable cable types. Any quality EIA485, twisted pair, 120 ohm, shielded cable will also work.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Installation Procedures Reflector Selection Users have the option of using one of the two supplied reflectors - one Peaked Reflector (installed in unit) and one Flat Field Reflector (stored in the luminaire’s head assembly under the bottom head cover) - with the VL3015 Spot and VL3515 Spot Luminaires. For more information on changing the reflector, refer to “Reflector Change” on page 89 of this manual.
2 INSTALLATION : INSTALLATION PROCEDURES Step 3. While pulling up on locking mechanism release, fit keyed holes onto raised mounting buttons at bottom of enclosure. Slide forward and release locking mechanism to lock in place. Ensure brackets are locked securely. (Always face brackets in same direction as shown.) WARNING: Ensure that the bracket locking mechanism is fully seated after the bracket is installed on the luminaire.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Installing in Truss: Step 1. Using two people, lift luminaire into mounting position. Step 2. Secure in place with truss hook. Ensure truss hook hardware that locks hook in place (e.g. wing bolt) is properly tightened and that luminaire is fully supported. Step 3. Attach safety cable (as required) as follows: a. Connect one end of cable to luminaire handle. b. Loop at least once around truss/pipe and attach other end of cable to other handle.
INSTALLATION : INSTALLATION PROCEDURES 2 Floor Mounting the Luminaire The luminaire enclosure is sufficient to stabilize the luminaire in a floor installation, provided that the mounting surface is flat and sturdy. Luminaire Enclosure Figure 2-6: Floor Mounting Connecting Data and Power A maximum of 32 luminaires may be connected in any one DMX data link. Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data link path.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Powering Up Power Up and Configuration Procedure Since Lamp On is the default state, the lamp will strike when the luminaire is powered up for the first time. When AC power is applied and the luminaire’s power switch is in the "On" position, the luminaire will immediately begin a calibration sequence that steps it through pan and tilt movements. The internal color, gobo, and beam mechanisms will also move through a full range of motion.
INSTALLATION : ADDRESSING 2 Addressing Program Starting Address The address setting for DMX console controlled systems is entered using the Menu Display (refer to “Menu Operation” on page 64). The luminaire retains the DMX address even if power is removed. Note: Refer to your console operating instructions for specific information regarding its addressing requirements. Program a DMX starting address: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Address appears. Press [Enter].
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Notes 20 2 7 Au gu st 2 013 02 .9 679 .
CHAPTER 3. Operation This chapter contains instructions for operating the luminaire using DMX control and for updating the internal software. • VL3015 Spot DMX Channels • VL3015 Spot DMX Mapping • VL3015 Spot Luminaire Timing • VL3515 Spot DMX Channels • VL3515 Spot DMX Mapping • VL3515 Spot Luminaire Timing • Updating Software 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL VL3015 Spot DMX Channels VL3015 Spot Channel Mapping These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence. Table 1: VL3015 Spot DMX Channel Mapping DMX Channel Parameters Range (DMX) Range (%) Default Value* 1 Intensity 0 (closed) - 255 (open) 0 - 100% 0 0 - 65535 0 - 100% 32768 16 bit control of Pan 540°of movement.
OPERATION : VL3015 SPOT DMX CHANNELS 3 Table 1: VL3015 Spot DMX Channel Mapping DMX Channel Parameters 16 Gobo Wheel 2 17 G2 Index Rt High 18 G2 Index Rt Low 19 Gobo Wheel 3 20 G3 Index Rt High 21 G3 Index Rt Low 22 Beam Iris Range (DMX) Range (%) Default Value* 0 - 255 0 - 100% 0 0 - 65535 0 - 100% 32767 Description Controls Gobo Wheel 2 using the following levels from 0 to 216. From 217 to 255 will give different speeds of wheel spin. DMX values . . .
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 1: VL3015 Spot DMX Channel Mapping DMX Channel Parameters Range (DMX) Range (%) Default Value* Description Used to strike/douse the lamp, set lamp levels, and other various functions, as well as resetting the luminaire via the console.
OPERATION : VL3015 SPOT DMX CHANNELS 3 VL3015 Spot Control Channel Functions Control channel functions allow special actions such as reset, lamp on/off and partial recalibration. These must be executed with zero time transition or with timing disabled. Discrete values must be used; not manual controls such as faders or encoders (see chart below for values). Reset - resets all luminaire mechanisms. Lamp On or Lamp Off - switches lamp on or off.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Step 3. Set control channel value to zero. (This must occur without any scaling values. Action will be voided if other values are detected between action value and zero.) Note: A numerical keypad is required for sending values. An encoder or fader does not allow for a quick value change, which is required to effect the control functions. 26 2 7 Au gu st 2 013 02 .9 679 .
OPERATION : VL3015 SPOT DMX MAPPING 3 VL3015 Spot DMX Mapping VL3015 Spot Color Control The luminaire’s color system is composed of a color mixing mechanism and a fixed color wheel. The follow sections describe these components. Color Mixing The color mixing mechanism is made up of four graduated color disks: blue, amber, magenta and CTO (color temperature orange). These disks provide full-spectrum color crossfades from pastel to saturated color.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-3: VL3015 Spot Color Wheel Standard Configuration Chart Position Color Filter Part Number 1 Congo Blue 41.9678.0305.03 2 Orange 41.9678.0305.05 3 Kelly Green 41.9678.0305.02 4 Dark Fuchsia 41.9678.0305.06 5 Magenta 41.9678.0305.04 6 Deep Red 41.9678.0305.01 Table 3-4: VL3015 Spot DMX Map for Fixed Color Wheel 28 Position DMX Value Action 1 0 Open 1.5 15 Half 2 31 Center 2.5 48 Half 3 62 Center 3.
OPERATION : VL3015 SPOT DMX MAPPING 3 VL3015 Spot Beam Control Strobe Table 3-5: VL3015 Spot DMX Map for Strobe % Value DMX Value Action 0 0-2 Open 1 3-5 Closed 2 6-7 Slow Random 3 8-10 Med Random 4 11-12 Fast Random 5-100 13-255 Speed Range VL3015 Spot Gobo/Effects Control Gobo Wheels 1 and 2 These wheels have six positions, one being open.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-7: VL3015 Spot Gobo Wheel 2 Standard Configuration Chart Position Gobo Style Part Number 1 open n/a 2 Palm Leaves 41.6030.5503 3 Shock Break-up 41.6030.7018 4 Uneven Bars 41.6030.4211 5 Ice Blocks Gag 41.6030.8509 6 Droplets Gag 41.6030.8506 Gobo Wheel 3 This wheel has five positions, one being open.
OPERATION : VL3015 SPOT DMX MAPPING 3 Index/Rotation The gobo wheels operate in two modes: INDEX Mode and ROTATE Mode. The corresponding values are given in the DMX Map Tables below. Gobos will also behave as follows: • Gobo wheels will only stop at whole images. • It is not necessary for the wheel to complete a full revolution to change a gobo from indexing mode to rotating mode. • Timed moves are only available using the Gobo Time channel (27).
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL VL3015 Spot Luminaire Timing VL3015 Spot Timing Channel Information Timing channel control improves the timed moves of certain groups of parameters. We provide up to four timing channels, one for focus (Pan and Tilt), one for color parameters, one for beam parameters, and one for gobo wheel position (spot version only).
OPERATION : VL3015 SPOT LUMINAIRE TIMING 3 A timing value of zero is full speed. A time value of 100% (or 255 in DMX) enables the associated parameter(s) to follow cue fade time (console time) rather than the timing channel. Note: The particular storing syntax for your console, as well as instructions on how to write part cues, can be found in the operation manual for that console. To use these channels, you must: Step 1. Create the cue, including color, gobo, edge and diffusion as required. Step 2.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-13: Timing Channels Map (Continued) % Value DMX 8 20 4 21 4.2 22 4.4 23 4.6 24 4.8 25 5 26 5.2 27 5.4 28 5.6 29 5.8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 34 = Seconds 30 6 31 6.2 32 6.4 33 6.6 34 6.8 35 7.0 36 7.2 37 7.4 38 7.6 39 7.8 40 8 41 8.2 42 8.4 43 8.6 44 8.8 45 9 46 9.2 47 9.4 48 9.6 49 9.8 50 10 51 10.2 52 10.4 53 10.
OPERATION : VL3015 SPOT LUMINAIRE TIMING 3 Table 3-13: Timing Channels Map (Continued) % Value DMX = Seconds 62 14 63 15 25 64 15 65 16 26 66 16 67 16 27 28 29 30 17 17 70 18 71 18 72 18 73 19 74 19 75 20 76 20 77 20 78 21 79 21 80 21 81 22 32 82 22 83 23 33 84 23 85 23 31 34 35 36 37 86 24 87 24 88 25 89 25 90 25 91 26 92 26 93 27 94 27 95 27 96 28 38 97 28 98 29 39 99 29 100 29 40 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-13: Timing Channels Map (Continued) % Value DMX 104 31 41 105 31 106 32 107 32 108 32 109 33 110 33 111 34 112 34 113 34 42 43 44 114 35 45 115 35 116 36 46 117 36 118 36 47 48 49 50 51 119 37 120 37 121 38 122 38 123 38 124 39 125 39 126 39 127 40 128 40 129 41 130 41 131 41 132 42 52 133 42 134 43 53 135 43 136 43 54 55 56 57 36 = Seconds 137 44 138 44 139 4
OPERATION : VL3015 SPOT LUMINAIRE TIMING 3 Table 3-13: Timing Channels Map (Continued) % Value DMX = Seconds 146 47 147 48 58 148 48 149 49 59 150 49 151 49 60 61 62 63 50 50 154 50 155 51 156 51 157 52 158 52 159 52 160 53 161 53 162 54 163 54 164 54 165 55 65 166 55 167 56 66 168 56 169 56 64 67 68 69 70 170 57 171 57 172 58 173 58 174 58 175 59 176 59 177 59 178 60 179 60 180 65 181 65 182 65 183 70 72 184 70 185
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-13: Timing Channels Map (Continued) % Value DMX 188 80 74 189 80 190 85 191 85 192 85 193 90 194 90 195 95 196 95 75 76 77 197 95 198 100 78 199 100 200 110 79 201 110 202 110 80 81 82 83 84 203 120 204 120 205 120 206 130 207 130 208 140 209 140 210 140 211 150 212 150 213 160 214 160 215 160 216 170 85 217 170 218 180 86 219 180 220 180 87 88 89 38 = Seconds 221
OPERATION : VL3015 SPOT LUMINAIRE TIMING 3 Table 3-13: Timing Channels Map (Continued) % Value DMX = Seconds 90 230 220 231 230 232 230 233 230 91 234 240 92 235 240 236 250 93 237 250 238 250 94 95 96 260 260 241 270 242 270 243 270 244 280 245 280 246 290 247 290 248 290 249 300 98 250 300 251 310 99 252 310 253 310 97 100 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL VL3515 Spot DMX Channels VL3515 Spot Channel Mapping These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence. Table 4: VL3515 Spot DMX Channel Mapping DMX Channel Parameters Range (DMX) Range (%) Default Value* 1 Intensity 0 (closed) - 255 (open) 0 - 100% 0 0 - 65535 0 - 100% 32768 16 bit control of Pan 540°of movement.
OPERATION : VL3515 SPOT DMX CHANNELS 3 Table 4: VL3515 Spot DMX Channel Mapping DMX Channel Parameters Gobo Wheel 2 (Fixed Gobo) 16 Range (DMX) 0 - 255 Range (%) Default Value* 0 - 100% Description 0 Controls Gobo Wheel 2 using the following levels from 0 to 216. From 217 to 255 will give different speeds of wheel spin.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL • Use of Timing Channels: The default value setting in the profile should be 255 (proportional control) to allow smooth movement when using console timing. The Timing channel data should change as a snap. A zero value will give the fastest move but without any smoothing, this can look steppy in console-timed moves.
OPERATION : VL3515 SPOT DMX CHANNELS 3 To use control channel functions: Step 1. Select an action to be sent*. Step 2. Set control channel value for desired action (for example, 84 for reset). Hold value for 3 seconds. Step 3. Set control channel value to zero. (This must occur without any scaling values. Action will be voided if other values are detected between action value and zero.) Note: A numerical keypad is required for sending values.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL VL3515 Spot DMX Mapping VL3515 Spot Dimmer Wheel The luminaire is equipped with a graduated glass dimmer wheel. The dimmer wheel allows for smooth timed fades from full light output to absolute black. VL3515 Spot Color Control The luminaire’s color system is composed of a color mixing mechanism and a fixed color wheel. The follow sections describe these components.
OPERATION : VL3515 SPOT DMX MAPPING 3 Fixed Color Wheel The fixed color wheel offers fast or timed changes, partial and full frame positions, and various spin rates in either direction. The wheel contains seven positions, one being open.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-4: DMX Map for Fixed Color Wheel Position DMX Value Action 4.5 109 Half 5 124 Center 5.5 140 Half 6 155 Center 6.5 171 Half 7 186 Center 7.5 201 Half Table 3-5: DMX Map for Fixed Color Wheel Spin 46 % DMX Value Wheel Spin / Direction 85 - 91 217 - 233 Fast to Slow / CCW 92 234 - 236 Stop 93 - 100 237 - 255 Slow to Fast / CW 2 7 Au gu st 2 013 02 .9 679 .
OPERATION : VL3515 SPOT DMX MAPPING 3 VL3515 Spot Beam Control Strobe A dual blade strobe and dousing system provide variable strobe effects capable of slow, medium, fast, random, and plus a synchronized variable rate (up to 14 Hz.) operation. The strobe blades can be used to augment fades or rapid dousing (blocking of the beam) of the luminaire. Table 3-6: VL3515 Spot DMX Map for Strobe 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL VL3515 Spot Gobo/Effects Control Gobo Wheel 1 (Rotating) and 2 (Fixed) Gobo Wheel 1 has six positions, one being open. The gobo wheel assembly can spin and individual gobos can rotate. Gobo Wheel 2 is fixed with seven positions with one being open. Fixed means only the gobo wheel will spin.
OPERATION : VL3515 SPOT DMX MAPPING 3 Index/Rotation The rotating gobo wheel operates in two modes: INDEX Mode and ROTATE Mode. The corresponding values are given in the DMX Map Tables below. Gobos will also behave as follows: • Gobo wheels will only stop at whole images. • It is not necessary for the wheel to complete a full revolution to change a gobo from indexing mode to rotating mode. • Timed moves are only available using the Gobo Time channel (30).
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL The Gobo Index function utilizes 16-bit control which offers enhanced resolution whether in INDEX or ROTATE mode. Table 3-13: VL3515 Spot Index Rotation Range Function 50 Range Index 0-65535 Rotate 0 (cw max) - 32599 (cw min) 32600 - 33047 (stop) 33048 - 65535 (ccw max) 2 7 Au gu st 2 013 02 .9 679 .
OPERATION : VL3515 SPOT DMX MAPPING 3 VL3515 Spot Shutter Control Shutter Mechanism The shutter mechanism is comprised of four frame blades that move independently or in unison on two planes for a crisp, sharp image (refer to Figure 3-6 below). The entire assembly operates in a smooth, time-continuous motion using stepper motors (two per frame blade and one to rotate the entire shutter mechanism). The shutter mechanism can rotate 50o in either direction and the frame blades can tilt +/30o. .
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL VL3515 Spot Luminaire Timing VL3515 Spot Timing Channel Information Timing channel control improves the timed moves of certain groups of parameters. We provide up to four timing channels, one for focus (Pan and Tilt), one for color parameters, one for beam parameters, and one for gobo wheel position (spot version only).
OPERATION : VL3515 SPOT LUMINAIRE TIMING 3 A timing value of zero is full speed. A time value of 100% (or 255 in DMX) enables the associated parameter(s) to follow cue fade time (console time) rather than the timing channel. Note: The particular storing syntax for your console, as well as instructions on how to write part cues, can be found in the operation manual for that console. To use these channels, you must: Step 1. Create the cue, including color, gobo, edge and diffusion as required. Step 2.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-16: Timing Channels Map (Continued) % Value DMX 8 20 4 21 4.2 22 4.4 23 4.6 24 4.8 25 5 26 5.2 27 5.4 28 5.6 29 5.8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 54 = Seconds 30 6 31 6.2 32 6.4 33 6.6 34 6.8 35 7.0 36 7.2 37 7.4 38 7.6 39 7.8 40 8 41 8.2 42 8.4 43 8.6 44 8.8 45 9 46 9.2 47 9.4 48 9.6 49 9.8 50 10 51 10.2 52 10.4 53 10.
OPERATION : VL3515 SPOT LUMINAIRE TIMING 3 Table 3-16: Timing Channels Map (Continued) % Value DMX = Seconds 62 14 63 15 25 64 15 65 16 26 66 16 67 16 27 28 29 30 17 17 70 18 71 18 72 18 73 19 74 19 75 20 76 20 77 20 78 21 79 21 80 21 81 22 32 82 22 83 23 33 84 23 85 23 31 34 35 36 37 86 24 87 24 88 25 89 25 90 25 91 26 92 26 93 27 94 27 95 27 96 28 38 97 28 98 29 39 99 29 100 29 40 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-16: Timing Channels Map (Continued) % Value DMX 104 31 41 105 31 106 32 107 32 108 32 109 33 110 33 111 34 112 34 113 34 42 43 44 114 35 45 115 35 116 36 46 117 36 118 36 47 48 49 50 51 119 37 120 37 121 38 122 38 123 38 124 39 125 39 126 39 127 40 128 40 129 41 130 41 131 41 132 42 52 133 42 134 43 53 135 43 136 43 54 55 56 57 56 = Seconds 137 44 138 44 139 4
OPERATION : VL3515 SPOT LUMINAIRE TIMING 3 Table 3-16: Timing Channels Map (Continued) % Value DMX = Seconds 146 47 147 48 58 148 48 149 49 59 150 49 151 49 60 61 62 63 50 50 154 50 155 51 156 51 157 52 158 52 159 52 160 53 161 53 162 54 163 54 164 54 165 55 65 166 55 167 56 66 168 56 169 56 64 67 68 69 70 170 57 171 57 172 58 173 58 174 58 175 59 176 59 177 59 178 60 179 60 180 65 181 65 182 65 183 70 72 184 70 185
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 3-16: Timing Channels Map (Continued) % Value DMX 188 80 74 189 80 190 85 191 85 192 85 193 90 194 90 195 95 196 95 75 76 77 197 95 198 100 78 199 100 200 110 79 201 110 202 110 80 81 82 83 84 203 120 204 120 205 120 206 130 207 130 208 140 209 140 210 140 211 150 212 150 213 160 214 160 215 160 216 170 85 217 170 218 180 86 219 180 220 180 87 88 89 58 = Seconds 221
OPERATION : VL3515 SPOT LUMINAIRE TIMING 3 Table 3-16: Timing Channels Map (Continued) % Value DMX = Seconds 90 230 220 231 230 232 230 233 230 91 234 240 92 235 240 236 250 93 237 250 238 250 94 95 96 260 260 241 270 242 270 243 270 244 280 245 280 246 290 247 290 248 290 249 300 98 250 300 251 310 99 252 310 253 310 97 100 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Updating Software USB Download and Programming To download files with a PC equipped with a Universal Serial Bus (USB) port, you need the VARI❋LITE USB Luminaire Programming Kit (28.8500.0054). The USB Luminaire Programming Kit can be ordered directly from your Authorized VARI❋LITE Dealer. The VARI❋LITE USB Luminaire Programming Kit (28.8500.0054) includes: • VARI❋LITE USB Upload Cable (25.9600.0001) • USB Luminaire Programming Kit CD (87.8500.
OPERATION : UPDATING SOFTWARE Lists specific versions of downloaded software (on PC) Click to download specific software version to connected luminaire(s) 3 Device Connection Status and USB Downloader Controls Click logo to go to Vari-Lite web site (internet connection required) Download History Will show current progress of download Figure 3-7: VL Download Program Window Transferring Software From Luminaire to Luminaire It is possible to transfer specific software versions between luminaires.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL A DMX termination connector is used in this process. Refer to page 13 for more information regarding the construction of this connector.
CHAPTER 4. Menu System This chapter contains instructions for operating the luminaire using the Menu Display feature. • Menu Operation • Menu Functions • Self-Tests 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Menu Operation What Is the Menu System? The menu system is a programmable set of commands used to configure, address, operate, and test the luminaire. The menu system is controlled at the Menu Display available at the enclosure input panel. Menu Display ~ AC IN DATA IN DATA THRU MENU ENTER Figure 4-1: Menu Display Location Controls Operation The menu system is controlled by four buttons. These buttons function as follows: [Menu] button.
MENU SYSTEM : MENU OPERATION 4 To enter the menu system, first press [Menu]. The functions displayed will be 1st level functions. Scroll through the 1st level functions by pressing [Up] / [Down] arrows. Once the desired function appears in the display, press [Enter]. You are now at the 2nd level. Once again, press the [Up] / [Down] arrows to scroll through 2nd level functions. Press [Enter] to access 3rd level functions and so forth.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Menu Functions VL3015 Spot Menu System Overview The following is a graphic representation of the entire menu system.
MENU SYSTEM : MENU FUNCTIONS 4 VL3015 Spot Menu System Function Chart The following is a detailed look at the internal menu system.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 4-1: VL3015 Spot Menu System Chart 1st Level Test 2nd Level 3rd Level All @1 Test All mechanisms at once, 2 steps RUN TEST Run-Test in Progress All SEQ Test all mechanisms in order, X steps.
MENU SYSTEM : MENU FUNCTIONS 4 Table 4-1: VL3015 Spot Menu System Chart 1st Level Manual Manual Commands 2nd Level 3rd Level Pan * XXXX Value Tilt * XXXX Value Dimmer XXX Value Strobe XXX Value Blue XXX Value Amber XXX Value Magenta XXX Value ColWheel Color Wheel XXX Value CTO Color Temperature Orange XXX Value Gobo1 (Spot Only) XXXX Value Index1 (Spot Only) XXX Value Gobo2 (Spot Only) XXX Value Index2 (Spot Only) XXX Value Gobo3 (Spot Only) XXX Value Index3 (Spot Only) XXX
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL VL3515 Spot Menu System Overview The following is a graphic representation of the entire menu system.
MENU SYSTEM : MENU FUNCTIONS 4 VL3515 Menu System Function Chart The following is a detailed look at the internal menu system.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Table 4-2: VL3515 Menu System Chart 1st Level Manual Manual Commands 72 2nd Level 3rd Level Pan * XXXX Value Tilt * XXXX Value Dimmer XXX Value Strobe XXX Value Cyan XXX Value Yellow XXX Value Magenta XXX Value ColWheel Color Wheel XXX Value CTO Color Temperature Orange XXX Value RotGobo XXXX Value Index1 XXX Value FixGobo XXX Value RotShut XXX Value Frame 1A XXX Value Frame 1B XXX Value Frame 2A XXX Value Frame 2B
MENU SYSTEM : MENU FUNCTIONS 4 Table 4-2: VL3515 Menu System Chart 1st Level Test 2nd Level 3rd Level All @1 Test All mechanisms at once, 2 steps RUN TEST Run-Test in Progress All SEQ Test all mechanisms in order, X steps. Pan/Tilt Pan Tilt Dimmer Strobe Cyan Yellow Magenta ColrMix CTO ColorWh1 RotGobo RUN TEST Run-Test in Progress 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Menu Function Definitions For easy reference, each possible menu item is listed alphabetically in the first column by its display abbreviation. The second column follows with a definition of the abbreviation and then a third column provides an explanation of its purpose and function. Table 4-3: Menu Function Definitions Display 74 Definition Purpose 10 Min 10 Minutes Sets Menu Display to automatically shut off after 10 minutes of non-use.
MENU SYSTEM : MENU FUNCTIONS 4 Table 4-3: Menu Function Definitions (Continued) Display Definition Purpose Index1 Gobo Index Specifies rotating the gobo index for manual control (Manual) and testing (Test) (EOT sensor, etc.) Inv Pan Invert Pan Reverses pan action for special focus requirements. Inv Tilt Invert Tilt Reverses tilt action for special focus requirements. Lamp Lamp Lamp OFF Lamp is Off Configures arc luminaire so that lamp will not strike upon power up.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Self-Tests Running Parameter Tests The luminaire is capable of running self-tests by using the Test menu functions. When running tests on multiple luminaires, a DMX termination connector is required at the last luminaire in the link. Refer to “Connecting Data and Power” on page 17 for more information regarding the construction of this connector.
MENU SYSTEM : SELF-TESTS 4 Movement Disable The Movement option allows pan and tilt to be disabled so that the luminaire can be placed in any position for testing without movement occurring. In order to regain full control of the luminaire, Movement will need to be enabled after testing. Note: When using the Movement option, pan and tilt will be disabled for all the luminaires that are linked. To set movement option: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Config appears.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Notes 78 2 7 Au gu st 2 013 02 .9 679 .
APPENDIX A. Luminaire Care and Routine Maintenance This appendix provides instructions for troubleshooting and routine maintenance which may be necessary during the life of the luminaire. • Equipment Handling • Troubleshooting • Routine Maintenance WARNING: All maintenance procedures are to be performed with power removed from the luminaire. Never remove covers or backcap while lamp is in operation. 02.96 79.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Equipment Handling Below are some basic tips and information on handling luminaires and their associated components. Locations/Use VARI❋LITE luminaires are designed for dry locations only. Exposure to rain or moisture (including, but not limited to, fog machines, misters, etc.,) may damage luminaire. Lamps Servicing • When handling a lamp, hold it by the ceramic base while wearing cotton gloves or finger cots. Do not touch the glass envelope (bulb).
TROUBLESHOOTING AND MAINTENANCE A compounds is greater around the top electrode than the bottom electrode. In addition, the fill components that are difficult to vaporize congeal around the bottom electrode, thereby reducing lamp life. Solid State Electronics Electrostatic Discharge (ESD) Electrostatic discharge (ESD) presents a significant danger to solid state electronic components (semiconductor devices and PC board assemblies).
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Troubleshooting Error Messages If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu Display will cycle through any applicable error message(s) until the end of the list is reached. To review the error messages again, it will be necessary to access them using the Status function. To access error messages: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Fixture appears. Press [Enter].
TROUBLESHOOTING AND MAINTENANCE A Troubleshooting Guide If a problem is suspected, first try recalibrating the luminaire to prompt an error message. The chart below provides possible causes and remedies for various error messages and/or symptoms. Table A-2: Troubleshooting Chart Message Symptom Description Lamp Power Douse Lamp does not strike upon start-up Lamp Off option is configured n/a Lamp douses frequently Lamp Douse Fan failure... - check fans for proper connection and operation.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Routine Maintenance Lamp Replacement WARNING: Ensure that power is removed from luminaire when installing lamp. CAUTION: Wear cotton gloves or other covering while installing lamp. Touching lamp glass with bare fingers will leave oil and may cause the lamp to explode or reduce lamp life. If touched, use alcohol and cotton cloth to thoroughly clean glass portion of lamp. To replace lamp: Step 1. Ensure power is removed from luminaire. Step 2.
TROUBLESHOOTING AND MAINTENANCE A Align Lamp The design of the VL3015 / VL3515 Spot Luminaire optical system allows for a flat or peaked field. A flat field is one where there is no detectable hot spot and a peaked field is one where the intensity of the beam is greater at the center of the beam than at the perimeter. After a new lamp or an alternative reflector (refer “Reflector Change” on page 89) is installed, it will be necessary to align the lamp to optimize the beam.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Gobo Replacement - Gobo Wheels (Rotating and Fixed) Tools: #2 Phillips screwdriver WARNING: Remove power from luminaire before performing maintenance. Gobos may be HOT after operation. Allow to cool before replacing. To replace a gobo: Step 1. Remove power from luminaire. Step 2. Remove appropriate head cover by loosening four 1/4-turn screws: a. To access Wheel 1, remove bottom cover as shown in Figure A-3. b.
TROUBLESHOOTING AND MAINTENANCE A * Head covers are attached by tethers. Top Head Cover * 1/4-Turn Screw (4 per head cover) Bottom Head Cover * Gobo Wheel (see detail) ROTATING GOBO WHEELS Gobo Assembly Rotating Gobo Wheel Front of luminaire Carrier CAUTION: Do not touch glass with bare fingers. Press on gobo carrier only.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Color Filter Replacement Tools: #2 Phillips screwdriver WARNING: Remove power from luminaire before performing maintenance. Filters may be HOT after operation. Allow to cool before replacing. To replace a color filter: Step 1. Remove power from luminaire. Step 2. Remove top head cover by loosening four 1/4-turn screws as shown in Figure A-4. CAUTION: Do not touch filters with bare fingers. Wear cotton gloves or other covering while replacing.
TROUBLESHOOTING AND MAINTENANCE A Reflector Change The VL3015 Spot and VL3515 Spot luminaires come with both a Peaked and Flat Field Reflector. Users can choose between either reflector as desired. Note: The unit, when shipped from the factory, has the Peaked Reflector installed in the unit’s hot box and the Flat Field Reflector stored in the luminaire head assembly underneath the bottom head cover.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Step 5. As shown in Figure A-6, remove stored reflector by removing acorn nut and foam washer securing reflector in luminaire head assembly. Set reflector aside on a soft clean cloth. Reflector Assembly Storage Location Reflector Assembly Acorn Nut Foam Washer Figure A-6: Reflector Removal (From Storage Location) Step 6.
TROUBLESHOOTING AND MAINTENANCE Step A 8. Using a flat screwdriver, remove current reflector from hot box assembly as follows: a. Press tabs (one on each side) securing reflector assembly into hot box (as shown in Figure A-8), inwards to release reflector assembly. b. Gently pull reflector assembly straight up and away from hot box assembly. CAUTION: You must remove lamp before removing reflector assembly. Do not touch reflector with bare fingers. Wear cotton gloves.
VARI❋LITE VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Cleaning Optics, Filters and Gobos WARNING: Remove power from luminaire before performing maintenance. WARNING: Acetone is a harsh cleaning agent and solvent. Acetone is very flammable. Please handle acetone according to manufacturer’s safety instructions and precautions. The front lens, optics/color filters, and reflector may require cleaning after extended use.
APPENDIX B. Technical Specifications VL3015 Spot Luminaire PROGRAMMABLE FUNCTIONS Zoom Optics 13-element 6:1 zoom optics system covering a range of 10° to 60°. Color System A three-filter CYM cross-fading mechanism. A fixed color wheel with six interchangeable color filters and continuous wheel rotation for additional effects. It includes a variable CTO color temperature correction filter. Intensity Control Full field dimming designed for both smooth timed fades and quick dimming effects.
VARI❋LITE - VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL Reflector Precision glass reflector with dichroic cold mirror coating. Color Filter Fixed wheel color filters: .044" thick, 2.039" diameter. Gobo Gobos are E size. Metal gobos are not acceptable. OPERATIONAL Power Requirements Standard AC power distribution from 200-264 VAC, 50/60 Hz. The unit requires 8 to 12 A depending on the AC supply voltage. Operational Temperatures -20° to 104°F (-29° to 40°C) Cooling Forced air cooled.
TECHNICAL SPECIFICATIONS B PHOTOMETRIC 1500W Short Arc Lamp (Flat Field Reflector) Zoom Lens Position CENTER BEAM CANDELA CENTER BEAM FOOT-CANDLE TOTAL LUMENS FIELD ANGLE (degrees) FIELD DIAMETER TN* NFOV 1,483,115 4,734 21,592 9.7 0.1695 MFOV 225,449 4,601 21,408 24.2 0.4286 WFOV 39,968 5,098 21,918 57.
VARI❋LITE - VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL VL3515 Spot Luminaire PROGRAMMABLE FUNCTIONS Zoom Optics 13-element 6:1 zoom optics system covering a range of 10° to 60°. Color System A three-filter CYM cross-fading mechanism. A fixed color wheel with six interchangeable color filters and continuous wheel rotation for additional effects. It includes a variable CTO color temperature correction filter.
TECHNICAL SPECIFICATIONS B Gobo Gobos are E size. Metal gobos are not acceptable. OPERATIONAL Power Requirements Standard AC power distribution from 200-264 VAC, 50/60 Hz. The unit requires 8 to 12 A depending on the AC supply voltage. Operational Temperatures -20° to 104°F (-29° to 40°C) Cooling Forced air cooled. Control Compatible with a wide variety of DMX512 consoles. Weight 94 lbs. (43 kg) Spacing Hangs on 26.0 inch (66 cm) centers. Luminaire can be mounted and operated in any orientation. 20.
VARI❋LITE - VL3015 / VL3515 SPOT LUMINAIRE USER’S MANUAL PHOTOMETRIC 1500W Short Arc Lamp (Flat Field Reflector) Zoom Lens Position CENTER BEAM CANDELA CENTER BEAM FOOT-CANDLE TOTAL LUMENS FIELD ANGLE (degrees) FIELD DIAMETER TN* NFOV 1,483,115 4,734 21,592 9.7 0.1695 MFOV 225,449 4,601 21,408 24.2 0.4286 WFOV 39,968 5,098 21,918 57.
Philips Vari-Lite 10911 Petal Street Dallas, Texas 75238 USA 1-877-VARI-LITE . 1-214-647-7880 www.vari-lite.com. ©2013 Philips Vari-Lite, a Philips group company. All Rights Reserved.