Installation manual
Example: MX00Z460101 - Clear input sensitivity preset number 01, sub-
preset 01.
The response from the SVS-88 will be:
MX00-sensitivity preset 0101 cleared
MXxxZ47pp - Save current SVS-88 settings as preset.
xx = unit ID number (00 – 15, default = 00)
pp = preset number (01-16)
Example: MX00Z4701 - Save current SVS-88 settings as preset 01.
The response from the SVS-88 will be:
MX00-Preset 01 saved
MXxxZ48pp – Show settings of a preset.
xx = unit ID number (00 – 15, default = 00)
pp = preset number (01-16)
Example: MX00Z4801 - Show current SVS-88 settings defined to preset 01 (the
display of a defined preset may be extensive,
including up to 8 preset items of each function type,
i.e. audio, video, digital, etc.)
The response from the SVS-88 will be:
MX00-digital preset 0101 set 02 to 01
MX00-video preset 0101 set 03 to 05
MXxxZ49pp - Run a preset.
xx = unit ID number (00 – 15, default = 00)
pp = preset number (01-16)
Example: MX00Z4901 - Run a defined preset (the execution of a defined
preset may be extensive, including up to 8 preset
items of each function type, i.e. audio, video, digital,
etc.)
The response from the SVS-88 will be:
MX00-Digital=02 to 01
MX00-Video=03 to 05
MXxxZ55pp - Delete a preset.
xx = unit ID number (00 – 15, default = 00)
36