If you are installing a door sensor, use definition 01 and type normally closed.
If you are installing a motion detector, use definition, 04 and type normally closed.
If you are installing a glass break detector, use definition 01 and type normally closed.
If you are installing an outdoor motion detector, use definition 16 and normally closed.
If you have any indoor sensors but shouldn't activate any alarms, set them to definition 16 and
normally closed.
When hooking up the doorbell, choose the Fast loop response, definition 16 and normally closed.
When hooking up garage door sensor, use definition 16 and normally closed.
If you are hooking up a fire alarm detection system, use zone 15 and 16. Zone 15 should be the
power monitoring system. This should be set to definition 16 and normally closed. Zone 16 should be
set to definition 10 and type 5, if it's a four wire system. No attributes for any of these.
It's also important to name each zone for the consumer's logs.
Wireless Setup
Clients may take advantage of wireless technology in their home. To setup the ELK wireless module
right click on the input tab and choose New Wireless Expander. You can only have one wireless card
per unit, they come in 8, 16, and 48 zone cards. Once installed, the zones will work the same as
regular onboard zones. You will have to enroll all the wireless devices after you have uploaded the
system. See below for instructions.
Keyfob Setup
Some users might want to take advantage of a Keyfob to control their system. To allow control you
must setup the keyfob in the Wireless Setup screen. The buttons must be setup as follows.
If you are using a keyfob, you must enroll the fob into the system. See the wireless enrollment at the
below for more information. It is also important to know that the Keyfob will take up one zone on the
wireless system. You will need to set this zone to definition 15-Keyfob.