*The local programming code is set to 172839, this should be changed so other installers can not
access your system at the keypad level.
If you are having problems with the outdoor siren, you might have to switch the wires going into the
ELK output 2.
Make sure you save the configuration file so that you can access it later.
Once you have completed the entire settings configuration you are ready to update the ELK system.
Choose the Send/Rcv icon on the toolbar to send your data to the ELK system.
Changing the User's Code from the Keypad:
After you have setup the software and are ready to let the home owner create their own password for
the security system go to Menu 6 on the keypad. Choose user 1 and let them type in their new 4 or 6
digit code. After they have entered the new code choose exit. You will have to input the installers’
code to access screen 6.
Wireless Enrollment:
If you are using a wireless card you will need to enroll each device into the system after the wireless
card has been setup and uploaded to the ELK system.
1) Press the ELK key, then press 9 to display Installation Programming. Press the Right arrow key to
select this menu.
2) Enter the Installer Program Code.
3) Press 14 to access the Wireless Setup Menu, and then hit the Right arrow.
4) Press 3 to access the learn command, and then hit the Right arrow.
5) Choose which Zone you would like to learn first, make sure to match up the Zone you programmed
into the software with the Zone you learn to the system.
6) Press the Right arrow to activate learn mode. Go to the transmitter and press the tamper or enroll
button. The keypad should emit a short tone when the transmitter becomes enrolled.
7) Continue these steps for all the wireless devices in the house.
(If you are using a keyfob make sure you enroll this onto the zone you setup above for the keyfob. To
enroll the keyfob press the two bottom buttons at the same time (Light & Star).)
For advanced diagnostics you can view file ELK-M1_RS232_PROTOCOL on your EyeOn Technician
CD to get a list of the RS232 protocols. This device connects at 115200 BPS 8-N-1. You must use the
check sum generator to send commands with RS232. Use file M1_CRC_Calculator on your EyeOn
User Manual CD to download.