4.11 SECURITY: WebRelay (170001)
WebRelay is an electro-mechanical relay with a built-in web server. It can be controlled via the
Internet or a local
intranet. It is very simple to set up and use and has many features. There are 3
types of WebRelay devices that are integrated with the EyeOn Automation system: WebRelay,
WebRelay Dualm and WebRelay Quad.
To begin setup on the WebRelay hook up unit to power and network only. Next setup a computer on
the same network using an IP address of 192.168.1.2 and a Subnet Mask of 255.255.255.0. This will
be used to configure the relay.
Now login to http://192.168.1.2/setup.html with your web browser. (This is the default IP address). The
page is password protected. Enter ‘webrelay’ to gain access. Set the permant IP address in the
configuration page. Next power cycle the relay for the changes to take place. After the relay powers
back on the contacts can be connected. The computer can now be set back to it’s original settings.
The WebRelay can now be accessed using the new IP address.
NOTE:
For the Web Relay
Click “Relay / Input ” and change Relay Options to no local relay control.
For the Web Relay Dual
Click “Relay 1/ Input 1” and change Relay 1 Options to no local relay 1 control.
Click “Relay 2/ Input 2” and change Relay 2 Options to no local relay 2 control.
For the Web Relay Quad you must use Firefox to change the IP address.
.