4.12 CLIMATE CONTROL: RCS TR40 (060001)
Use file TR40 Owners Manual on your EyeOn Technician CD to view the TR40 owner's manual.
Use file TR40 Remote Temp Sensor Manual on your EyeOn Technician CD to view the TR40 remote
temperature sensor install manual. (OS21)
The TR40 has software that can communicate with it directly. This software is not needed to setup the
TR40 to work with the EyeOn system but might want to be used for trouble shooting. Use file TR40 on
your EyeOn Technician CD to download the software.
All devices in the climate section use a RS485 bus to send and receive data. Because of this we use
a RS485 hub to bring all climate devices together and then turn it into a standard RS232 input. The
hub has 8 Individual RS485 channels that allow home-run style wiring and a RS232 output. To hook
up more than 8 devices you will have to chain together an 8 port RS485 hub with RS485 output to the
input of an 8 Port RS485 hub with RS232 output. For a wiring diagram please view RS485 Hub Wiring
Diagram PDF on your EyeOn Technician CD.
Once all of the TR40 (For a wiring diagram use your EyeOn Technician CD to view file TR40
Diagram.gif, see owner's manual for install details) and Outdoor sensors have been installed you must
address each. The Outdoor sensor by default will be address 1 and can remain this way. You will
have to go up to each TR40 and set a unique address for the EyeOn system to communicate with.
Please write this information down.
Setting Address, Start with Address 2.
Press the far left button to access the menu section. Once you have entered the menu section press
and hold the two middle buttons until you enter Installers Settings.