4.22 TOUCH SCREEN: WinXP Pro 400MHz (100001)
All Touch Screens come from the EyeOn Service Center preconfigured. An IP is already set and each
screen will act as a computer on the network. Touch Screens should be installed in the wall with the
proper mounting bracket and hooked up properly. A power wire and Cat5 cable (hooking into the
network hub in the server room) should be all that is connected to the screen.
EyeOn’s Touch Screen is a low-voltage device requiring a 24VDC power supply. It is designed and
programmed to work seamlessly with the EyeOn Server via a standard Ethernet connection. The
following sections describe the requirements for connecting the EyeOn touch screen with the EyeOn
Server.
Pre-wiring requirements
Before installing the EyeOn Touch Screen, you will need to pre-wire the mounting location with the
following cabling:
o 16-gauge/3-conductor Cable for 24VDC Power
o Category-5 or Category-6 Cable for Ethernet communication
The installer will need to run these cables from the touch screen’s location to the location where the
Ethernet router (or switch) and remote 24VDC power supply reside. (Refer to the EyeOn Resource
Center for more details about providing proper power and communication requirements
.
)
Terminations
Before terminating the communication and power cables, take a moment to familiarize yourself with
these connection points on the touch screen, shown in Figure 1 below.
Figure 1