Specifications

59
4.24 Access Control (120001)
A computer should be pre setup before it goes on site with the RFID Badge Software. You will need to
set the IP address to be on the local network for the computer. We have set the IP by default to
192.168.130.9. The computer is setup to communicate with 192.168.130.90 by default. If you need to
change this then:
Navigate to the following directory
C:\Program Files\Hitcents\IDBadgeCreator\
Then load Hitcents IDBadgeCreator.exe.config
Change ConnectionString & AccessServer ip address to the corrected IP address.
Once you have done this you will need to setup the username and password on the EyeOn Server.
On the EyeOn Server:
Hit Ctrl, Alt F2 to switch to a clean terminal
Login with username and password
mysql –p
#type installer password
use mysql;
#Change username and password to the correct username and password. You can make this
whatever you want.
grant all privileges on *.* to username@'192.168.130.9'
identified by 'password' with grant option;
grant all privileges on *.* to username@'localhost'
identified by 'password' with grant option;
exit
#Put in the same username and password for database to write logs
pico /home/homeauto/htdocs/datafiles/rfiddatabase.txt
User_Name½Password½
The first time you login, or any time you make a configuration change to EyeOn server for the Doors
you will need to hold control to make the system download the doors to the computer.
NStar Setup
You will need to have 1 NStar Panel per two RFID card readers. You will hook Reader 1 into TS3 and
card reader 2 into TS4. You will need to make sure you hook the ground up.
If you use the iClass cards here is the wire layout
Port 1 =Yellow and Orange
Port 2 =Green
Port 3 =White
Port 4=Black
Port 5=Red