Instruction Manual

WARNING!
3. Pre-Use Check
4. Filling
1) Do: Turn pump handle counterclockwise and remove pump
2) Do: Prepare spray solution following all directions and safety warnings on chemical label.
3) Do: Fill tank to no more than the proper gallon marker. Do NOT: over ll to accommodate pump.
4) Do: Check pump to make sure that no grass or dirt is stuck to barrel. Replace pump in tank and tighten securely.
9. Care, Storage and Maintenance
010538-8 (A) R0412
WARNING: Handling the brass parts of this product will expose you to lead, a chemical known
to the State of California to cause birth defects and other reproductive harm. Wash hands after
handling.
2. Nozzle
6-6136
Hose
Manguera
Tuyau
6-1898
Shut-o Handle
Mango de cierre
Poignée du robinet
6-3337
Straps
Tirantes
Sangles
For constant spraying, push down on shut-o
handle and move locking mechanism away from
you. To release, squeeze handle and move the
locking mechanism back towards you.
6. Fatigue-Free Spraying
Note: Your particular sprayer may not include all parts pictured above.
Nota: Es posible que este pulverizador en particular no incluya todas las partes que se ilustran arriba.
Remarque : Votre pulvérisateur particulier pourrait ne pas inclure toutes les pièces illustrées plus haut.
Attach nozzle to shut-o handle or extension wand.
Parts, Piezas, Pièces
6-6141
Hose Brown
Manguera Castaño
Tuyau Brun
6-5943
Nozzle 1.0 GPM
Tobera
Buse
6-7734
Extension wand, Vara de extensión, Rallonge
6-5797
Nozzle .5GPM
Tobera
Buse
6-7749
Extension wand, Vara de extensión, Rallonge
6-4638
Shut-o Handle
Mango de cierre
Poignée du robinet
6-6003
Nozzle
Tobera
Buse
6-000
Nozzle
Tobera
Buse
3-7727
Extension wand, Vara de extensión, Rallonge
Repair Parts Kit Gaskets and Seals (not included),
Juego de piezas de reparación, empaquetaduras y juntas (no incluido)
Kit de pièces de réparation, joints et garniture d’étanchéité (non inclus) 6-4601
6A
Locking
mechanism
6B
2A
2B
1. Hose to Tank
Discharge/ Assembly
• Make sure white outlet tube is attached to outlet tube adapter (Fig. 1A).
Insert the outlet tube portion of the discharge assembly into the tank adapter (Fig. 1B).
Proper placement of white outlet tube (Fig. 1C).
Firmly insert the outlet tube adapter into the tank adapter (Fig. 1D) Lining up tab with notches on the tank adapter.
Firmly tighten the retaining nut to the tank adapter (Fig. 1E).
Discharge
Assembly
1B
Outlet
Tube
1E
Retaining Nut -
Securely tightened.
1C 1D
No
Gap
Tank
Adapter
Outlet Tube
Adapter
Tab/
Notch
1A
Outlet Tube
Adapter
Outlet
Tube
Sk-1154-1
WARNING: Improper use or failure to follow instructions can result in explosive failure causing serious
eye or other injury. For safe use of this product you must read and follow all instructions. Do not leave a pres-
surized sprayer in the hot sun. Heat can cause pressure build-up resulting in possible explosion. Do not store or
leave solution in tank after use. Always wear goggles, gloves, long sleeve shirt, long pants and full foot protec-
tion when spraying. Never use any tool to remove pump if there is pressure in sprayer. Never stand with face or
body over top of tank when pumping or loosening pump to prevent ejecting pump assembly and/or solution
from striking and injuring you. Never pressurize sprayer by any means other than the original pump. Do not
attempt to modify this sprayer. Replace parts only with manufacturer’s original parts. Never spray ammable,
caustic, acidic, chlorine, bleach or other corrosive solutions or heat, pressure, or gas producing chemicals.
Always read and follow chemical manufacturers instructions before use with this sprayer as some chemi-
cals may be hazardous when used with this sprayer.
1) Do: Check tightness of hose nut to be sure hose is securely attached to the tank outlet.
2) Do: Inspect hose for deterioration, cracks, softness, or brittleness. If any of these conditions are found, replace hose
before using. Replace with original manufacturer’s parts only.
3) Do: Remove pump (see Filling, Pressurizing and Spraying Instructions), inspect interior and exterior of tank for signs
of deterioration of body and bottom. Any sign of deterioration indicates possible tank weakening and could result in
explosive bursting under pressure. If any of these signs are found, discard tank immediately and replace. Do not
attempt to patch leaks, etc., as this could result in serious injury.
4) Do: Follow Filling, Pressurizing and Spraying Instructions, except use water only (Pump plunger 10-20 strokes and
inspect for leaks).
5) Do: Direct shut-o away from you and open to make sure discharge is not clogged.
6) Do: If unit passes this test, release pressure (see Pressure Releasing Instructions), empty tank, and proceed with Filling,
Pressurizing and Spraying Instructions.
7) Do: Inspect all metal parts including the wand, nozzle and ttings for rust, corrosion and pitting. If any of these
conditions are found, replace aected part with original manufacturers part before using.
1) Do: Rinse tank thoroughly with water only, empty, rell with water. Follow Filling, Pressurizing and Spraying
Instructions, except pump unit only 8-10 strokes. Be sure that the wand and nozzle are thoroughly rinsed with
water after each use.
2) Do: Open shut-o and allow water to run through discharge assembly.
3) Do: Release pressure (Follow Pressure Release Instructions), remove pump and empty sprayer.
4) Do: Store sprayer tank upside down, with pump removed, in a warm dry location.
5) Do: Periodically oil pump by dropping 10-12 drops of light oil down pump rod through opening in cover.
6-4605
Pressure Relief Valve
Válvula de descarga de presión
Soupape de décompression
6. Pressurizing and Spraying
Do: Turn handle clockwise to
tighten. Push handle down,
turn 1/4 turn counterclock-
wise to release.
Do: Pump until you
feel resistance.
Do: Push handle, down, turn
1/4 turn clockwise to lock. Begin
spraying. Re-pump sprayer as
required to maintain spray force.
6A
6C
6B
7. To Release Pressure
1) Your sprayer is equipped with a pressure relief/release valve
(Fig. 7A). To release pressure lift and hold the cap until air
is completely exhausted, OR, turn the valve slowly counter
clockwise until you hear air escaping and wait air is completely
exhausted (Fig. 7B).
2) Do: Stay away from the sprayer until all air has escaped.
7A 7B
8. Wand Dock Clip
Choose the holder that ts your wand.
10. Troubleshooting
-
Tank pressurizes but does not spray.
WARNING:
Release pressure in tank before troubleshooting.
Clean Nozzle Assembly (Fig. 10E)
-Remove nozzle cap by unscrewing. Clean and re-assemble.
Clean shut-off (Fig. 10A- 10D)
10E
Nozzle Cap
Pull handle straight
up.
Insert notches from
underside of handle
into plunger grooves
and turn counter-
clockwise.
Tighten plunger clockwise until
ush to top of shut-o body. Do
not over-tighten or unit may not
spray. Slide forks under plunger,
push handle down until it snaps
into place.
10A
10B
Handle
10D
Plunger ush
with body
Remove plunger, diaphragm and
spring. Wash diaphragm with
mild detergent. Reassemble:
Hold shut-o upright as shown,
place spring in hole, place
diaphragm on top of spring.
Reassemble plunger and tighten.
10C
Plunger
Spring
Diaphragm

Summary of content (2 pages)