3. Pre-Use Check
4. Filling
1) Do: Turn pump handle counterclockwise and remove pump
2) Do: Prepare spray solution following all directions and safety warnings on chemical label.
3) Do: Fill tank to no more than the proper gallon marker. Do NOT: over fill to accommodate pump.
4) Do: Check pump to make sure that no grass or dirt is stuck to barrel. Replace pump in tank and tighten securely.
018381R0322
2. Nozzle
6-5370
Extension wand
Vara de extensión
Rallonge
6-5371
Shut-off Handle
Mango de cierre
Poignée du robinet
6-5372
Nozzle
Tobera
Buse
2A 2B
1. Hose to Tank
Discharge/ Assembly
• Make sure white outlet tube is attached to outlet tube adapter (Fig. 1A).
Insert the outlet tube portion of the discharge assembly into the tank adapter (Fig. 1B).
Proper placement of white outlet tube (Fig. 1C).
Firmly insert the outlet tube adapter into the tank adapter (Fig. 1D) Lining up tab with notches on
the tank adapter.
Firmly tighten the retaining nut to the tank adapter (Fig. 1E).
Discharge
Assembly
1B
Outlet
Tube
1E
Retaining Nut -
Securely tightened.
1C 1D
No
Gap
Tank
Adapter
Outlet Tube
Adapter
Tab/
Notch
1A
Outlet Tube
Adapter
Outlet
Tube
Attach nozzle to shut-off handle or extension wand.
1) Do: Check tightness of hose nut to be sure hose is securely attached to the tank outlet.
2) Do: Inspect hose for deterioration, cracks, softness, or brittleness. If any of these conditions are found,
replace hose before using. Replace with original manufacturer’s parts only.
3) Do: Remove pump (see Filling, Pressurizing and Spraying Instructions), inspect interior and exterior of tank for
signs of deterioration of body and bottom. Any sign of deterioration indicates possible tank weakening and could
result in explosive bursting under pressure. If any of these signs are found, discard tank immediately and replace.
Do not attempt to patch leaks, etc., as this could result in serious injury.
4) Do: Follow Filling, Pressurizing and Spraying Instructions, except use water only (Pump plunger 10-20 strokes
and inspect for leaks).
5) Do: Direct shut-off away from you and open to make sure discharge is not clogged.
6) Do: If unit passes this test, release pressure (see Pressure Releasing Instructions), empty tank, and proceed with
Filling, Pressurizing and Spraying Instructions.
7) Do: Inspect all metal parts including the wand, nozzle and fittings for rust, corrosion and pitting. If any of these
conditions are found, replace affected part with original manufacturer’s part before using.
9. Troubleshooting
-
Tank pressurizes but does not spray.
WARNING:
Release pressure in tank before troubleshooting.
Clean Nozzle Assembly (Fig. 9E)
Clean shut-off (Fig. 9A- 9D)
9E
Nozzle Cap
Pull handle
straight up.
Insert notches from
underside of handle
into plunger grooves
and turn counter
-
clockwise.
Remove plunger. Wash
diaphragm in mild dish
detergent.
Tighten plunger clockwise until
flush to top of shut-off body. Do
not over-tighten or unit may not
spray. Slide forks under plunger,
push handle down until it snaps
into place.
9A 9B 9C
Handle
Plunger
Body
Rubber
Diaphragm
9D
Plunger flush
with body
5. Pressurizing and Spraying
5A5A
5C5C
5B5B
6-4606
Pressure Relief Valve
Válvula de descarga de presión
Soupape de décompression
WARNING: Improper use or failure to follow instructions can result in explosive failure causing
serious eye or other injury. For safe use of this product you must read and follow all instructions. Do
not leave a pressurized sprayer in the hot sun. Heat can cause pressure build-up resulting in possible
explosion. Do not store or leave solution in tank after use. Always wear goggles, gloves, long sleeve
shirt, long pants and full foot protection when spraying. Never use any tool to remove pump if there is
pressure in sprayer. Never stand with face or body over top of tank when pumping or loosening pump
to prevent ejecting pump assembly and/or solution from striking and injuring you. Never pressurize
sprayer by any means other than the original pump. Do not attempt to modify this sprayer. Replace
parts only with manufacturer’s original parts. This sprayer is designed for acidic solutions only.
Never spray flammable, chlorine or bleach, caustic, or other corrosive solutions or heat, pressure,
or gas producing chemicals. Always read and follow chemical manufacturer’s instructions
before use with this sprayer as some chemicals may be hazardous when used with this sprayer.
Sk-1159-1
WARNING
6-6136
Hose
Manguera
Tuyau
Parts, Piezas, Pièces
Note: Your particular sprayer may not include all parts pictured above.
Nota: Es posible que este pulverizador en particular no incluya todas las partes que se ilustran arriba.
Remarque : Votre pulvérisateur particulier pourrait ne pas inclure toutes les pièces illustrées plus haut.
Congratulations!
You have just purchased a quality Chapin product.
Register Your Sprayer Online @ www.chapinmfg.com Questions? Do Not Return To Store.
Call us @ 1-800-950-4458 or www.chapinmfg.com
6-4602
Repair Parts Kit Gaskets and Seals (not included),
Juego de piezas de reparación, empaquetaduras y
juntas (no incluido)
Kit de pièces de réparation, joints et garniture
d’étanchéité (non inclus)
Do: Turn handle clockwise
to tighten. Push handle
down, turn 1/4 turn
counterclockwise to
release.
Do: Pump until you
feel resistance.
Do: Push handle, down, turn 1/4 turn
clockwise to lock. Begin spraying. Re-
pump sprayer as required to maintain
spray force.
6. To Release Pressure
1) Your sprayer is equipped with a pressure relief/release
valve (Fig. 6A). To release pressure lift and hold the cap
until air is completely exhausted, OR, turn the valve
slowly counterclockwise until you hear air escaping
and wait air is completely exhausted (Fig. 6B).
2) Do: Stay away from the sprayer until all air has
escaped.
6A6A 6B6B
8. Wand Dock Clip
Choose the holder that fits your wand.
7. Care, Storage and Maintenance
P.O. Box 549 700 Ellicott St.
Batavia, NY 14021-0549 U.S.A.
1-800-950-4458 www.chapinmfg.com
1) Do: Follow chemical manufacture’s instructions for cleaning. Rinse thoroughly with recommended solvent.
Follow Filling, Pressurizing and Spraying Instructions, except pump unit only 8-10 strokes. Be sure that the
wand and nozzle are thoroughly rinsed after each use.
2) Do: Open shut-off and allow recommended solvent to run through discharge assembly.
3) Do: Release pressure (Follow Pressure Release Instructions), remove pump and empty sprayer.
4) Do: Store sprayer tank upside down, with pump removed, in a warm dry location.
5) Do: Periodically oil pump by dropping 10-12 drops of light oil down pump rod through opening in cover.
Remove nozzle cap by unscrewing. Clean and re-assemble.