Use and Care Manual
6-4626
Shut-off Handle
Mango de cierre
Poignée du robinet
2. Nozzle
Attach nozzle to shut-off handle or extension wand.
6-6003
Nozzle
Tobera
Buse
6. To Release Pressure
1) Do: With pump facing away, turn locked handle counterclockwise until air begins to escape.
Stop turning handle when you hear air escaping.
2) Do: Stay away from the sprayer until all air has escaped.
6-7756
Extension wand
Vara de extensión, Rallonge
(31010, 31020, 31030, 36140)
6-7749
Extension wand
Vara de extensión, Rallonge (30220)
8A
Locking
mechanism
2B2A
5. Pressurizing and Spraying
Pump until you
feel resistance.
Turn handle clockwise
to tighten. Push handle
down, turn 1/4 turn
counterclockwise to
release.
Push handle, down,
turn 1/4 turn clockwise
to lock. Begin spraying.
Re-pump sprayer as
required to maintain
spray force.
Adjust spray pattern by
turning nozzle cap. Do
not turn cap more than 2
turns or cap may come off
allowing spray material to
spray back on you.
5C5C
5B5B
5A5A
5D5D
Pull handle
straight up.
Insert notches from
underside of handle into
plunger grooves and turn
counterclockwise.
Tighten plunger clockwise until flush to top of shut-off body. Do not
over-tighten or unit may not spray. Slide forks under plunger, push
handle down until it snaps into place.
9. Troubleshooting
-
Tank pressurizes but does not spray.
9A
9B
Handle
WARNING:
Release pressure in tank before troubleshooting.
Clean Nozzle Assembly (Fig. 9E)
-
Remove nozzle cap by unscrewing.
Clean and re-assemble.
Clean shut-off (Fig. 9A- 9D)
9E
Nozzle Cap
9D
Plunger flush
with body
Remove plunger, diaphragm and spring. Wash
diaphragm with mild detergent. Reassemble: Hold
shut-off upright as shown, place spring in hole,
place diaphragm on top of spring. Reassemble
plunger and tighten.
9C
Plunger
Spring
Diaphragm
Sk-1154-1
WARNING: Improper use or failure to follow instructions can result in explosive failure causing serious
eye or other injury.
For safe use of this product you must read and follow all instructions. Do not leave
a pressurized sprayer in the hot sun. Heat can cause pressure build-up resulting in possible explosion.
Do not store or leave solution in tank after use. Always wear goggles, gloves, long sleeve shirt, long pants
and full foot protection when spraying. Never use any tool to remove pump if there is pressure in sprayer.
Never stand with face or body over top of tank when pumping or loosening pump to prevent ejecting pump
assembly and/or solution from striking and injuring you. Never pressurize sprayer by any means other than
the original pump. Do not attempt to modify this sprayer. Replace parts only with manufacturer’s original
parts. Never spray flammable, caustic, acidic, chlorine, bleach or other corrosive solutions or heat,
pressure, or gas producing chemicals. Always read and follow chemical manufacturer’s instructions
before use with this sprayer as some chemicals may be hazardous when used with this sprayer.
WARNING
018029R1221
6-1925
Repair Parts Kit Gaskets and Seals (not included),
Juego de piezas de reparación, empaquetaduras y juntas (no incluido)
Kit de pièces de réparation, joints et garniture d’étanchéité (non inclus)
Parts, Piezas, Pièces
6-6136
Hose
Manguera
Tuyau
6-3337
Carrying Strap
Correa para cargar
Sangle de transport
Note: Your particular sprayer may not include all parts pictured above.
Nota: Es posible que este pulverizador en particular no incluya todas las partes que se ilustran arriba.
Remarque : Votre pulvérisateur particulier pourrait ne pas inclure toutes les pièces illustrées plus haut.
Congratulations!
You have just purchased a quality Chapin product.
Register Your Sprayer Online @ www.chapinmfg.com Questions? Do Not Return To Store.
Call us @ 1-800-950-4458 or www.chapinmfg.com
Make sure hose is pushed all the way to the tank.
Make sure hose clamp is tight and below the hose barb.
Turn clockwise with a screwdriver to tighten.
Hose Barb
1. Hose to Tank
To ensure the long life of your sprayer, after every use thoroughly rinse the tank, funnel and pump when
cleaning your sprayer. Residual chemical can attack the seals, metal and TriPoxy coating.
Avoid chipping and/or denting of the inside and outside of the tank. Any exposed steel is prone to chemical
attack and can cause poor performance or even failure.
Never store sprayer with chemical left in the tank and thoroughly clean after each use. Seek out Chemical
manufacturer’s instructions for specific chemical compatibility information.
CAUTION
3. Pre-Use Check
1) Do: Check tightness of hose nut to be sure hose is securely attached to the tank outlet.
2) Do: Inspect hose for deterioration, cracks, softness, or brittleness. If any of these conditions are
found, replace hose before using. Replace with original manufacturer’s parts only.
3) Do: Remove pump (see Filling, Pressurizing and Spraying Instructions), inspect interior and
exterior of tank for signs of deterioration of body and bottom. Any sign of deterioration indicates
possible tank weakening and could result in explosive bursting under pressure. If any of these
signs are found, discard tank immediately and replace. Do not attempt to patch leaks, etc., as this
could result in serious injury.
4) Do: Follow Filling, Pressurizing and Spraying Instructions, except use water only
(Pump plunger 10-20 strokes and inspect for leaks).
5) Do: Direct shut-off away from you and open to make sure discharge is not clogged.
6) Do: If unit passes this test, release pressure (see Pressure Releasing Instructions), empty tank,
and proceed with Filling, Pressurizing and Spraying Instructions.
7) Do: Inspect all metal parts including the wand, nozzle and fittings for rust, corrosion and pitting.
If any of these conditions are found, replace affected part with original manufacturer’s part
before using.
4. Filling
1) Do: Turn pump handle counterclockwise and remove pump.
2) Do: Prepare spray solution following all directions and safety warnings on chemical label.
3) Do: Fill tank to no more than the proper gallon marker. Do NOT: over fill to accommodate pump.
4) Do: Check pump to make sure that no grass or dirt is stuck to barrel. Replace pump in tank and
tighten securely.
8. Fatigue-Free Spraying
For constant spraying, push down on shut-off handle
and move grey locking mechanism away from you.
To release, squeeze handle and move the grey locking
mechanism back towards you. ( Not all models are
provided with this feature).
7. Care, Storage and Maintenance
1) Do: Follow chemical manufacture’s instructions for cleaning. Rinse thoroughly with
recommended solvent. Follow Filling, Pressurizing and Spraying Instructions, except pump unit
only 8-10 strokes. Be sure that the wand and nozzle are thoroughly rinsed after each use.
2) Do: Open shut-off and allow recommended solvent to run through discharge assembly.
3) Do: Release pressure (Follow Pressure Release Instructions), remove pump and empty sprayer.
4) Do: Store sprayer tank upside down, with pump removed, in a warm dry location.
5) Do: Periodically oil pump by dropping 10-12 drops of light oil down pump rod through opening
in cover.
P.O. Box 549 700 Ellicott St.
Batavia, NY 14021-0549 U.S.A.
1-800-950-4458 www.chapinmfg.com