Use and Care Guide

4
Installation Safety Precautions
Use grill, as purchased, only with LP (propane) gas and the
regulator/valve assembly supplied.
Grill installation must conform with local codes, or in their
absence of local codes, with either the National Fuel Gas
Code, ANSI Z223.1/ NFPA 54, Natural Gas and Propane
Installation Code, CSA B149.1, or Propane Storage and
Handling Code, B149.2.
All electrical accessories (such as rotisserie) must be
electrically grounded in accordance with local codes, or
National Electrical Code, ANSI / NFPA 70 or Canadian
Electrical Code, CSA C22.1. Keep any electrical cords
and/or fuel supply hoses away from any hot surfaces.
This grill is safety certified for use in the United States
and/or Canada only. Do not modify for use in any other
location. Modification will result in a safety hazard.
USE AND CARE
LP Cylinder Removal, Transport and Storage
•Turn OFF all control knobs and LP cylinder valve. Turn coupling
nut counterclockwise by hand only - do not use tools to
disconnect. Loosen cylinder screw beneath bottom shelf or
disconnect other retention means, then lift LP cylinder up and
and out of cart. Install safety cap onto LP cylinder valve.
Always use cap and strap supplied with valve. Failure to use
safety cap as directed may result in serious personal
injury and/or property damage.
•A disconnected LP cylinder in storage or being transported
must have a safety cap installed (as shown). Do not store an
LP cylinder in enclosed spaces such as a carport, garage,
porch, covered patio or other building. Never leave an LP
cylinder inside a vehicle which may become overheated by the
sun.
•Do not store an LP cylinder in an area where children play.
LP Cylinder Valve
Retainer Strap
Safety Cap
LP Cylinder
•The LP cylinder used with your grill must meet the
following requirements:
Use LP cylinders only with these required measurements: 12"
(30.5cm) (diameter) x 18" (45.7 cm) (tall) with 20 lb. (9 kg.)
capacity maximum.
•LP cylinders must be constructed and marked in accordance
with specifications for LP cylinders of the U.S. Department of
Transportation (DOT) or for Canada, CAN/CSA-B339, cylinders,
spheres and tubes for transportation of dangerous goods,
Transport Canada (TC). See LP cylinder collar for marking.
LP cylinder valve must have:
•Type 1 outlet compatible with
regulator or grill.
•Safety relief valve.
•UL listed Overfill Protection Device (OPD). This
OPD safety feature is identified by a unique
triangular hand wheel. Use only LP cylinders
equipped with this type of valve.
OPD Hand
Wheel
•LP cylinder must be upright for vapor withdrawal and include
collar to protect LP cylinder valve. Always keep LP cylinders in
upright position during use, transit or storage.
LP cylinder in upright position
for vapor withdrawal
LP (Liquefied Petroleum Gas)
LP gas is nontoxic, odorless and colorless when produced. For
Your Safety, LP gas has been given an odor (similar to rotten
cabbage) so that it can be smelled.
LP gas is highly flammable and may ignite unexpectedly when
mixed with air.
LP Cylinder Filling
Use only licensed and experienced dealers.
LP dealer must purge new cylinder before filling.
Dealer should NEVER fill LP cylinder more than 80% of LP
cylinder volume. Volume of propane in cylinder will vary by
temperature.
A frosty regulator indicates gas overfill. Immediately close
LP cylinder valve and call local LP gas dealer for assistance.
•Do not release liquid propane (LP) gas into the atmosphere.
This is a hazardous practice.
•To remove gas from LP cylinder, contact an LP dealer or call a
local fire department for assistance. Check the telephone
directory under “Gas Companies” for nearest certified LP
dealers.

Summary of content (8 pages)