User's Manual

ChargePoint® Charging Stations
1-2
Specifications
Electrical input
Input Power: 7.2 kW
Input Voltage: 208/240 VAC
Input Current: 30 A
Input Power Connections: Line 1, Line 2, Earth
Required Service Panel Breaker: Dual 40 A double pole breaker (non-GFCI type) on dedicated circuit
Standby Power: 5 W typical
Electrical output
Output Charging Power: 7.2 kW
Output Voltage: 208/240 VAC
Output Current: 30 A
Output Charging Connector: SAE J1772
TM
EV connector on 18’ (5m) cable
Functional interfaces
Card Reader: ISO 15693, 14443
Ground Fault Detection: 20 mA CCID with auto retry (15 minute delay, 3 tries)
Plug-Out Detection: Power terminated per SAE J1772
TM
specification
Power Measurement: 2% at 15 minute intervals
Local Area Network: 2.4 GHz 802.15.4 dynamic mesh network
Wide Area Network: Commercial CDMA or GPRS cellular data network
Safety and operational ratings
Safety Compliance: UL Listed for USA and cUL certified for Canada; Complies with UL 2594, UL 2231-1,
UL 2231-2, UL 1998, UL 991, NEC Article 625
Surge Protection: 6 kV @ 3000 A. In geographic areas subject to frequent thunder storms, supplemental
surge protection is recommended.
EMC Compliance: FCC Part 15 Class B
Operating Temperature: -22°F to 122°F (-30°C to +50°C)
Operating Humidity: Up to 95% non-condensing
Enclosure: NEMA 3R
Terminal Block Temperature Rating: 212°F (100°C)
Maximum Charging Stations per 802.15.4 Radio Group: 100. Each station must be within 150 feet “line
of sight” of at least one other station.