Technical Specifications

32
Plastics Technical Manual
>> CPVC Copper Tube Size Pipe
NOTE: STRAIGHT LENGTH PIPE ARE SHIPPED IN FULL BUNDLE QUANTITY ONLY.
FlowGuard Gold
®
Pipe
NSF Listed. Meets All Requirements of ASTM D 2846.
STRAIGHT LENGTHS PLAIN END SDR 11 CPVC COPPER TUBE SIZE PIPE ASTM D 2846
TRUCKLOAD MAX WORK
PART NO. NOM. SIZE UPC # QTY. PER PERCENT QTY. PER AVG. OD (IN.) MIN. WALL PRESSURE WT. PER
611942- BUNDLE PER SKID SKID (IN.) AT 23° C OR 73° F 100 FT. (LBS.)
CTS 12005
1
2
x 10’ 04979 500’ 2.083 12,000’ .625 .068 400 PSI 8.3
CTS 12005
1
2
x 20’ 04993 1,000’ 5.000 24,000’ .625 .068 400 PSI 8.3
CTS 12007
3
4
x 10’ 04980 250’ 2.083 6,000’ .875 .080 400 PSI 13.9
CTS 12007
3
4
x 20’ 05145 500’ 5.000 12,000’ .875 .080 400 PSI 13.9
CTS 12010 1
x 10’ 05146 150’ 2.083 3,600’ 1.125 .102 400 PSI 22.2
CTS 12010 1
x 20’ 05147 300’ 5.000 7,200’ 1.125 .102 400 PSI 22.2
CTS 12012 1
1
4
x 10’ 05148 100’ 2.083 2,400’ 1.375 .125 400 PSI 33.3
CTS 12012 1
1
4
x 20’ 05321 200’ 5.000 4,800’ 1.375 .125 400 PSI 33.3
CTS 12015 1
1
2
x 10’ 05150 60’ 2.083 1,440’ 1.625 .148 400 PSI 46.6
CTS 12015 1
1
2
x 20’ 05306 120’ 5.000 2,880’ 1.625 .148 400 PSI 46.6
CTS 12020 2
x 10’ 05152 40’ 2.083 960’ 2.125 .193 400 PSI 79.5
CTS 12020 2
x 20’ 05322 80’ 5.000 1,920’ 2.125 .193 400 PSI 79.5
CTS 12005
1
2
x 150’ 05313 150’ 4.166 3,750’ .625 .068 400 PSI 8.3
CTS 12007
3
4
x 100’ 05314 100’ 4.166 2,500’ .875 .080 400 PSI 13.9
CTS 12010 1
x 100’ 10643 100’ 4.166 1,200’ 1.125 .102 400 PSI 22.2
COILED PIPE SDR 11 COILED SDR CPVC COPPER TUBE SIZE PIPE ASTM D 2846
TRUCKLOAD MAX WORK
PART NO. NOM. SIZE UPC # QTY. PER PERCENT QTY. PER AVG. OD (IN.) MIN. WALL PRESSURE WT. PER
611942- BUNDLE PER SKID SKID (IN.) AT 23° C OR 73° F 100 FT. (LBS.)
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFAs website and
ASTM D 1785.
PRODUCT DATA
NOTE: Please call Charlotte Pipe at 800/438-6091 or visit our
website www.CharlottePipe.com for the latest CPVC Chemical
Compatibility Sheet.