Use And Care Manual

Piping System Applications
>> Cure Times
Minimum Cure Time to Test at 180 PSI
Cure times shown are sufficient to complete
a hydrostatic test at 100 PSI with 60%
humidity and cold water. Full cure may take
significantly longer.
Cure times are a function of air temperature,
water temperature, humidity and pipe size.
Increase the cure time for more demanding
conditions. For more specific information,
contact the cement manufacturer.
>> Special Considerations
Do NOT air test.
See CP&F Plastics Technical and Installation
Manual for chemical compatibility.
UV sensitivity.
Do NOT install permanently in direct
sunlight without painting with water-based
latex paint, or covering with insulation.
• Teflon
®
tape is the ONLY recommended
thread sealant.
PVC Schedule 80 Pipe & Fittings For Pressure Applications
Size 60˚- 100˚F 40˚- 60˚F - 40˚F
22
PVC Schedule 80 Pipe and Fittings
Notices, Cautions and Warnings Please refer to www.charlottepipe.com for all applicable notices, cautions and warnings
for this product group. You may also contact us at (800) 438-6091 for additional safety, installation or application
information. Notices: N-2; N-3; N-4; N-5; N-6; N-7; N-8; N-9; N-10; N-11; N-12; N-14; N-15; N-17; N-19; N-22;
N-27; N-32; N-34; N-38 Cautions: C-2, C-4, C-6, C-8 Warnings: W-2; W-3; W-4; W-5; W-6; W-9; W-12; W-13;
W-14; W-15; W-17; W-18; W-21; W-22; W-23; W-24; W-26; W-28; W-29; W-35; W-37
1/2" to 1-1/4"
1/2" to 3"
4" to 8"
10" to 16"
1 Hour
2 Hours
6 Hours
24 Hours
2 Hours
4 Hours
12 Hours
48 Hours
8 Hours
16 Hours
48 Hours
8 Days