Technical Specifications

95
INSTALLATION PROCEDURES
1
4 A
1
2 NR
3
8 A
1
2 NR
1
2 A
1
2 NR
3
4 A 1 NR
1 A 1 NR
1
1
4 A 1 NR
1
1
2 A 1 - 1
1
2 NR
2 A 1 - 1
1
2 NR
2
1
2 NR 1
1
2 - 2 NR
3 NR 1
1
2 - 2
1
2 NR
4 NR 2 - 3 3
6 NR 3 - 5 3
8 NR 4 - 6 7
10 NR 6 - 8 7
12 NR 6 - 8 7
14 NR 7 - 8 7
16 NR 8+ 8
A = Acceptable NR = Not Recommended
NOTICE: Rollers are not recommended.
Nominal Pipe
Size (in.)
Applicator Type
Dauber Brush Width (in.)
Swab Length (in.)
Applicator Types
Primers and cements are extremely flammable and may be
explosive. Do not store or use near open flame or elevated
temperatures, which may result in injury or death.
Solvent fumes created during the joining process are
heavier than air and may be trapped in newly installed
piping systems.
Ignition of the solvent vapors caused by spark or flame
may result in injury or death from explosion or fire.
Read and obey all manufacturers' warnings and any
instructions pertaining to primers and cements.
Provide adequate ventilation to reduce fire hazard and
to minimize inhalation of solvent vapors when working
with cements, primers and new piping systems.
Solvent Cement Color Primer
Pipe and Diameter Cement (common usage, Description (common usage,
Fitting System (in.) Standard check local code) check local code)
Regular or Not
ABS DWV 1
1
2
- 6 ASTM D 2235 Black Medium-Bodied Recommended
Regular or Not
ABS Plus
®
Foam Core Pipe 1
1
2
- 4 ASTM D 2235 Black Medium-Bodied Recommended
FlowGuard Gold
®
and
ReUze
®
CTS CPVC
1
2
- 2 ASTM F 493 Yellow Regular-Bodied Optional
IPS 714 or Oatey CPVC IPS P-70 or Oatey
CPVC Sch. 80
1
2
- 2 ASTM F 493 Heavy Duty Orange Heavy-Bodied Industrial Grade
IPS 714 or Oatey CPVC IPS P-70 or Oatey
CPVC Sch. 80 2
1
2
- 8 ASTM F 493 Heavy Duty Orange Heavy-Bodied Industrial Grade
ChemDrain Mustard 6” and larger: IPS P-70 or
CPVC Sch. 40 ChemDrain 1
1
4
- 8 ASTM F 493 Yellow (Required) Heavy-Bodied
Oatey Industrial Grade required
Regular or Required
PVC DWV or Sch. 40 Pressure
1
2
- 4 ASTM D 2564 Clear Medium-Bodied ASTM F 656
Medium or Required
PVC DWV or Sch. 40 Pressure 6 - 16 ASTM D 2564 Clear or Grey Heavy-Bodied ASTM F 656
Medium or Required
PVC Sch. 80
1
4
- 2 ASTM D 2564 Grey Heavy-Bodied ASTM F 656
IPS P-70 or Oatey
PVC Sch. 80 2
1
2
- 16 ASTM D 2564 Grey Heavy-Bodied Industrial Grade
Solvent Cements
NOTICE: Aerosol or spray-on type primers/solvent cements are not recommended. The practice of aggressively scouring the pipe
and fittings with both primer and solvent cement is an integral part of the joining process. Not working the primer or solvent
cement into the pipe or fitting could cause potential system failure or property damage.