Use And Care Manual

>> Cure Times
Minimum Cure Time to Test
Cure times shown are sufficient to complete
a hydrostatic test at 4.3 PSI with 60%
humidity and cold water. Full cure may
take significantly longer.
Cure times are a function of air temperature,
water temperature, humidity and pipe size.
Increase the cure time for more demanding
conditions.
>> Special Considerations
• Do NOT air test.
• Teflon
®
tape is the ONLY recommended
thread sealant.
• UV sensitivity.
• Do NOT install permanently in direct
sunlight without painting with water-based
latex paint or covering with insulation.
• Support every 4 feet.
PVC Schedule 40 DWV Pipe & PVC DWV Fittings For Non-Pressure Applications
1-1/4" to 3"
4" to 8"
10" to 12"
2 Hours
6 Hours
24 Hours
4 Hours
12 Hours
40 Hours
16 Hours
48 Hours
8 Days
14
Size 60˚- 100˚F 40˚- 60˚F - 40˚F
Piping System Applications
Notices, Cautions and Warnings Please refer to www.charlottepipe.com for all applicable notices, cautions and warnings
for this product group. You may also contact us at (800) 438-6091 for additional safety, installation or application
information. Notices: N-2; N-3; N-6; N-7; N-9; N-11; N-12; N-13; N-15; N-19; N-22; N-27; N-35; N-37; N-38
Cautions: C-2, C-4, C-6 Warnings: W-2; W-3; W-4; W-5; W-6; W-9; W-10; W-12; W-13; W-14; W-18; W-21; W-22;
W-23; W-24; W-26; W-28; W-29; W-30; W-31; W-35; W-37