>> Standards
ASTM D 1785 Schedule 40 Solid Wall
PVC Pipe
ASTM F 891 Cellular Core PVC DWV Pipe
ASTM D 2665 PVC DWV Pipe & Fittings
NSF Standard 14
>> Dimensional Standard
Schedule 40 Iron Pipe Size (IPS)
>> Cell Class
12454 PVC Solid Wall Pipe & Fittings
11432 PVC DWV Cellular Core Pipe
>> Maximum Working Temperature
140° F
>> Maximum Working Pressure
0 (zero) PSI
PVC DWV is NOT a pressure-rated
piping system.
Recommended test is 10 feet of hydrostatic
pressure, which equals 4.3 PSI.
>> Joining Method
Solvent Weld Joints
Solvent cements must meet ASTM D 2564.
Primer is required.
May be joined with a slip joint compression
fitting (a trap adapter, for example).
Threaded Joints
Threading PVC 40 pipe is NOT recommended.
MIP and FIP adapters are available.
PVC Schedule 40 DWV Pipe & PVC DWV Fittings For Non-Pressure Applications
13
Piping System Applications
PVC DWV Pipe and Fittings