How to Guide

24
Plastics Technical Manual
APA 17112 1
1
2
x 10’ 12495 2590’ 1.900 0.145 31.4
APA 17112 1
1
2
x 20’ 12494 5180’ 1.900 0.145 31.4
APA 17200 2
x 10’ 12497 1670’ 2.375 0.154 41.9
APA 17200 2
x 20’ 12496 3340’ 2.375 0.154 41.9
APA 17300 3
x 10’ 12499 750’ 3.500 0.216 84.0
APA 17300 3
x 20’ 12498 1500’ 3.500 0.216 84.0
APA 17400 4
x 10’ 12501 480’ 4.500 0.237 118.8
APA 17400 4
x 20’ 12500 960’ 4.500 0.237 118.8
>> ABS Plus® Schedule 40 DWV Pipe (For Non-Pressure Applications)
ABS Plus is a registered trademark of Charlotte Pipe and Foundry Company.
ABS Plus
®
Foam Core DWV Pipe
ABS PLUS
®
SCHEDULE 40 DWV PIPE (BLACK) PLAIN END ASTM F 1488
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD (IN.) MIN. WALL (IN.) WT. PER
611942- SKID 100 FT. (LBS.)
NSF Listed. Meets All Requirements of ASTM F 1488.
All products manufactured by Charlotte Pipe and
Foundry Company are proudly made in the U.S.A.
NOT FOR PRESSURE
Do not use PVC / ABS / ABS Plus
®
cellular core (foam core) pipe
for pressure applications. The use of cellular core pipe in
pressure applications may result in system failure and
property damage.
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFAs website and
ASTM D 1785.