GENERAL INFORMATION
SUBMITTAL FOR CHARLOTTE PIPE
®
PVC D 2729 SEWER AND DRAIN PIPE
Charlotte Pipe and Charlotte Pipe and Foundry Company are registered trademarks of Charlotte Pipe and Foundry Company.
FO-SUB-PVC-D-2729 (7-3-14)
Date: ________________
Job Name: ______________________________ Location: _______________________________
Engineer: _______________________________ Contractor: ______________________________
Scope:
This specication covers PVC D 2729 Sewer pipe for drainage applications. This systems is intended for drainage
applications where the operating temperature will not exceed 140°F.
Specication:
Pipe shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a cell class of 12454 as identied
in ASTM D 1784. PVC D 2729 Sewer Pipe dimensions and physical properties shall conform to ASTM D 2729. All pipe shall
be manufactured in the United States.
Installation:
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall conform to
all applicable plumbing, re, and building code requirements. Buried pipe shall be installed in accordance with ASTM D 2321
and ASTM F 1668. Solvent cement joints shall be made in a two-step process with primer conforming to ASTM F 656 and
solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, re-stopping materials,
thread sealant, plasticized-vinyl products or other aggressive chemical agents not compatible with PVC compounds. The
system shall be hydrostatically tested after installation WARNING! Never test with or transport/store compressed air or gas
in PVC pipe or ttings. Doing so can result in explosive failures and cause severe injury or death.
Referenced Standards:
ASTM D 1784 Rigid Vinyl Compounds
ASTM D 2729 PVC Sewer Pipe
ASTM D 2564 Solvent Cements for PVC Pipe and Fittings
ASTM F 656 Primers for PVC Pipe and Fittings
ASTM D 2321 Underground Installation of Thermoplastic Pipe (non-pressure applications)
ASTM F 1668 Procedures for Buried Plastic Pipe
PVC Sewer and Drain Pipe
Charlotte Pipe and Foundry Company • P.O. Box 35430 Charlotte, NC 28235 • (800) 438-6091 • www.charlottepipe.com
PVC ASTM D 2729 Pipe
SOLVENT WELD BELLED END ASTM D 2729
PVC 30030 3 x 10 10903 810 3.250 0.070 3.00 52.8
PVC 30040 4 x 10 10905 500 4.215 0.075 3.50 70.4
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL BELL DEPTH WT. PER
611942- SKID (IN.) (IN.) (IN.) 100 FT. (LBS.)
Perforated PVC ASTM D 2729 Pipe
SOLVENT WELD BELLED END ASTM D 2729
PVC 30030P
3 x 10 11814 1040 3.250 0.070 3.00 52.8
PVC 30040P
4 x 10 11815 500 4.215 0.075 3.50 70.4
PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL BELL DEPTH WT. PER
611942- SKID (IN.) (IN.) (IN.) 100 FT. (LBS.)
Weight is approximate and is for shipping purposes only.
Pipe listed meets or exceeds the requirements of ASTMD 2729.
Perforated pipe is supplied with two rows of 1/2 diameter holes every five inches.
Rows are parallel to the pipe axis and are 120° apart.
Perforation Detail
2-Hole 120 Degree