Dimensions Guide
26
Pipe Data
PVC 4005B**
1
⁄
2
” x 10’ 04986 .840 .109 600 PSI 2.00 15.9
PVC 4005B**
1
⁄
2
” x 20’ 03923 .840 .109 600 PSI 2.00 15.9
PVC 4007B**
3
⁄
4
” x 10’ 04987 1.050 .113 480 PSI 2.25 21.1
PVC 4007B**
3
⁄
4
” x 20’ 03926 1.050 .113 480 PSI 2.25 21.1
PVC 4010B** 1” x 10’ 04988 1.315 .133 450 PSI 2.50 31.3
PVC 4010B** 1” x 20’ 03929 1.315 .133 450 PSI 2.50 31.1
PVC 4012B
§
1
1
⁄
4
” x 10’ 04989 1.660 .140 370 PSI 2.75 42.4
PVC 4012B
§
1
1
⁄
4
” x 20’ 03930 1.660 .140 370 PSI 2.75 42.4
PVC 4015B
§
1
1
⁄
2
” x 10’ 04990 1.900 .145 330 PSI 3.00 51.8
PVC 4015B
§
1
1
⁄
2
” x 20’ 03931 1.900 .145 330 PSI 3.00 51.8
PVC 4020B
†
2” x 10’ 04991 2.375 .154 280 PSI 4.00 69.5
PVC 4020B
†
2” x 20’ 03932 2.375 .154 280 PSI 4.00 69.5
PVC 4025B
‡
2
1
⁄
2
” x 20’ 04206 2.875 .203 300 PSI 4.00 110.0
PVC 7300B
§
3” x 10’ 04853 3.500 .216 260 PSI 4.00 147.6
PVC 4030B
†
3” x 20’ 03933 3.500 .216 260 PSI 4.00 144.2
PVC 7400B
§
4” x 10’ 04835 4.500 .237 220 PSI 4.00 212.3
PVC 9400B
†
4” x 20’ 03964 4.500 .237 220 PSI 5.00 210.6
PVC 7600B
§
6” x 10’ 04850 6.625 .280 180 PSI 6.50 379.3
PVC 9600B
†
6” x 20’ 03965 6.625 .280 180 PSI 6.50 373.2
PVC 7800B
†
8” x 10’ 09903 8.625 .322 160 PSI 7.00 556.9
PVC 9800B
†
8” x 20’ 03967 8.625 .322 160 PSI 7.00 564.0
PVC 7910B
†
10” x 20’ 03960 10.750 .365 140 PSI 9.00 781.4
PVC 7912B
†
12” x 20’ 03962 12.750 .406 130 PSI 10.00 1033.2
PVC 7914B
†
14” x 20’ 04863 14.000 .437 130 PSI 10.00 1221.8
PVC 7916B
†
16” x 20’ 04929 16.000 .500 130 PSI 10.00 1594.5
M
A
D
E
I
N
U
.
S
.
A
.
PVC Schedule 40 Pipe - Bell End*
PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665
PVC SCHEDULE 40 (WHITE) BELL END PVC 1120 ASTM D 1785
MAX WORK
PART NO. NOM. SIZE UPC # AVG. OD MIN. WALL PRESSURE AT BELL DEPTH WT. PER
611942- (IN.) (IN.) 23° C OR 73° F (IN.) 100 FT. (LBS.)
* Bell dimensions meet either ASTM D 2672 or
ASTM F 480, depending upon pipe diameter
** ASTM D 1785
‡ Dual Marked ASTM D 1785 & ASTM F 480
§ Dual Marked ASTM D 1785 & ASTM D 2665
† Triple Marked ASTM D 1785 & ASTM D 2665 &
ASTM F 480
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
• NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
• Refer to warnings on PPFA’s website and
ASTM D 1785.