Installation Guide

87
Primers and cements are extremely flammable and may be
explosive. Do not store or use near open flame or elevated
temperatures, which may result in injury or death.
Solvent fumes created during the joining process are
heavier than air and may be trapped in newly installed
piping systems.
Ignition of the solvent vapors caused by spark or flame
may result in injury or death from explosion or fire.
Read and obey all manufacturers' warnings and any
instructions pertaining to primers and cements.
Provide adequate ventilation to reduce fire hazard and
to minimize inhalation of solvent vapors when working
with cements, primers and new piping systems.
• Remove excess
cement from the
exterior. A prop-
erly made joint
will show a con-
tinuous bead of
cement around
the perimeter. If
voids appear suf-
ficient cement
may not have
been applied and
joint failure may
result.
• Align all piping system components properly without
strain. Do not bend or pull pipe into position after being
solvent welded.
INSTALLATION PROCEDURES