Plastics Technical Manual
Product Specifications
System: ABS Cellular Core (Foam Core) Pipe and ABS DWV Fitting System
Scope: 5IJTTQFDJmDBUJPODPWFST"#4DFMMVMBSDPSFGPBNDPSFQJQFBOE"#4%87mUUJOHTVTFEJOTBOJUBSZ
ESBJOXBTUFBOEWFOU%87TFXFSBOETUPSNESBJOBHFBQQMJDBUJPOT5IJTTZTUFNJTJOUFOEFEGPSVTFJO
non-pressure applications where the operating temperature will not exceed 140°F.
Specification: Pipe shall be manufactured from virgin rigid ABS (acrylonitrile-butadiene-styrene) compounds with a
$FMM$MBTTPGBTJEFOUJmFEJO"45.%'JUUJOHTTIBMMCFNBOVGBDUVSFEGSPNWJSHJOSJHJE"#4
DPNQPVOETXJUIB$FMM$MBTTPGBTJEFOUJmFEJO"45.%
"#4DFMMVMBSDPSFQJQFTIBMMCF*SPO1JQF4J[F*14DPOGPSNJOHUP"45.'"#4%87mUUJOHT
TIBMMDPOGPSNUP"45.%1JQFBOEmUUJOHTTIBMMCFNBOVGBDUVSFEBTBTZTUFNBOECFUIFQSPEVDU
PGPOFNBOVGBDUVSFS"MMQJQFBOEmUUJOHTTIBMMCFNBOVGBDUVSFEJOUIF6OJUFE4UBUFT"MMTZTUFNTTIBMM
VUJMJ[FBTFQBSBUFXBTUFBOEWFOUTZTUFN1JQFBOEmUUJOHTTIBMMDPOGPSNUP/4'*OUFSOBUJPOBM4UBOEBSE
14.
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry
and shall conform to all applicable plumbing, fire, and building code requirements. Buried pipe shall
CFJOTUBMMFEJOBDDPSEBODFXJUI"45.%BOE"45.'4PMWFOUDFNFOUKPJOUTTIBMMCFNBEF
XJUIBTPMWFOUDFNFOUDPOGPSNJOHUP"45.%5IFTZTUFNTIBMMCFQSPUFDUFEGSPNDIFNJDBMBHFOUT
fire stopping materials, thread sealant, or other aggressive chemical agents not compatible with ABS
compounds. Systems shall be hydrostatically tested after installation. WARNING!/FWFSUFTUXJUIPS
USBOTQPSUTUPSFDPNQSFTTFEBJSPSHBTJO"#4QJQFPSmUUJOHT
Referenced Standards*:
"45.% 3JHJE"#4$PNQPVOET
"45.' $PFYUSVEFE"#41JQFXJUI$FMMVMBS$PSF
"45.% "#4%SBJO8BTUFBOE7FOU'JUUJOHT
"45.% 4PMWFOU$FNFOUTGPS"#41JQFBOE'JUUJOHT
"45.% 6OEFSHSPVOE*OTUBMMBUJPOPG5IFSNPQMBTUJD1JQFOPOQSFTTVSFBQQMJDBUJPOT
"45.' 1SPDFEVSFTGPS#VSJFE1MBTUJD1JQF
/4'4UBOEBSE 1MBTUJD1JQJOH$PNQPOFOUTBOE3FMBUFE.BUFSJBMT
/PUF-BUFTUSFWJTJPOPGFBDITUBOEBSEBQQMJFT
Short Specification:
Pipe and fittings shall be manufactured from ABS compound with a cell class of 42222
GPS QJQF BOE GPS GJUUJOHT BT QFS "45. % BOE DPOGPSN XJUI /4' *OUFSOBUJPOBM
4UBOEBSE1JQFTIBMMCFJSPOQJQFTJ[F*14DPOGPSNJOHUP"45.''JUUJOHTTIBMMDPOGPSNUP
"45.%
All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with
NBOVGBDUVSFST SFDPNNFOEBUJPOT BOE BQQMJDBCMF DPEF SFRVJSFNFOUT#VSJFEQJQFTIBMMCFJOTUBMMFE JO
BDDPSEBODFXJUI"45.%BOE"45.'4PMWFOUDFNFOUTIBMMDPOGPSNUP"45.%5IF
system is to be manufactured by Charlotte Pipe and Foundry Company and is intended for non-pressure
drainage applications where the temperature will not exceed 140°F.