47
Piping System Applications
>> Cell Class/Material Code
Cell Class: 12454 (Type 1)
Material Code: PVC 1120
>> Maximum Working Temperature
140° F
For special applications, threaded
connections, unions and flanges, a
temperature de-rating factor must be
used to determine the pressure rating
at temperatures hotter than 73° F.
Please visit www.charlottepipe.com for
additional information.
>> Maximum Working Pressure
See Product Offering/Data chart on page 47.
>> Joining Method
Solvent Weld Joints
Solvent cements must meet ASTM D 2564.
Primer should be IPS P-70 or Oatey
Industrial Grade.
May be flanged with Schedule 80 flanges.
Threading PVC 80 pipe can be done.
Please visit www.charlottepipe.com for
additional information.
Male Iron Pipe size (MIP) and Female
Iron Pipe size (FIP) adapters are available.
PVC Schedule 80 Pipe & Fittings For Pressure Applications
PVC Schedule 80 Pipe & Fittings