GENERAL INFORMATION
Schedule 80 and Schedule 40 Socket Diameter Schedule 80 Schedule 40
Nominal Entrance Bottom Tolerance Socket Length Socket Length
Size A B C (Minimum) C (Minimum)
1
2
0.848 0.836 ±0.004 0.875 0.688
3
4
1.058 1.046 ±0.004 1.000 0.719
1 1.325 1.310 ±0.005 1.125 0.875
1
1
4
1.670 1.655 ±0.005 1.250 0.938
1
1
2
1.912 1.894 ±0.006 1.375 1.094
2 2.387 2.369 ±0.006 1.500 1.156
2
1
2
2.889 2.868 ±0.007 1.750 1.750
3 3.516 3.492 ±0.008 1.875 1.875
4 4.518 4.491 ±0.009 2.250 2.000
6 6.647 6.614 ±0.011 3.000 3.000
8 8.655 8.610 ±0.015 4.000 4.000
10 10.780 10.735 ±0.015 5.000 5.000
12 12.780 12.735 ±0.015 6.000 6.000
Scope:
This specication covers PVC Schedule 40 pipe and ttings for pressure applications. This system is intended for
pressure applications where the operating temperature will not exceed 140° F.
Specication:
Pipe and ttings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a cell class of
12454 as identied in ASTM D 1784.
PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785. Injection molded PVC Schedule 40
ttings shall conform to ASTM D 2466. Pipe and ttings shall be manufactured as a system and be the product of one
manufacturer. All pipe and ttings shall be manufactured in the United States. Pipe and ttings shall conform to NSF
International Standard 61 or the health-effects portion of NSF Standard 14.
Installation:
Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall
conform to all applicable plumbing, re, and building code requirements. Buried pipe shall be installed in accordance
with ASTM F 1668. Solvent cement joints shall be made in a two-step process with primer conforming to ASTM F 656
and solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, re-stopping
materials, thread sealant, plasticized-vinyl products or other aggressive chemical agents not compatible with PVC
compounds. The system shall be hydrostatically tested after installation. WARNING! Never test with or transport/store
compressed air or gas in PVC pipe or ttings. Doing so can result in explosive failures and cause severe injury or
death.
Referenced Standards:
ASTM D 1784: Rigid Vinyl Compounds
ASTM D 1785: PVC Plastic Pipe, Schedule 40
ASTM D 2466: PVC Plastic Fittings, Schedule 40
ASTM D 2564: Solvent Cements for PVC
Pipe and Fittings
SUBMITTAL FOR CHARLOTTE PIPE
®
PVC SCHEDULE 40 PRESSURE PIPE AND FITTING SYSTEM
Charlotte Pipe and Charlotte Pipe and Foundry Company are registered trademarks of Charlotte Pipe and Foundry Company.
FO-SUB-PVC-40 (6-18-18)
Date: ________________
Job Name: ______________________________ Location: _______________________________
Engineer: _______________________________ Contractor: ______________________________
Not all tting
patterns shown
Bushing
Plug
Cap
Street Quarter
Bend
Cross
Eighth Bend
Quarter Bend
Male Adapter
Charlotte Pipe and Foundry Company • P.O. Box 35430 Charlotte, NC 28235 • (800) 438-6091 • www.charlottepipe.com
ASTM F 1668: Procedures for Buried Plastic Pipe
NSF Standard 14: Plastic Piping Components & Related Materials
NSF Standard 61: Drinking Water System Components –
Health Effects
Tee Coupling
Female Adapter
Schedule 40
Tapered Socket Dimensions
PVC SCHEDULE 40 - ASTM D 2466
Sizes Available
Product
1
2
3
4
1
1
1
4
1
1
2
2
2
1
2
3
4
5
6
8
10
12
14
16
PVC Schedule 40
PIPE REFERENCE GUIDE
M
A
D
E
I
N
U
.
S
.
A
.