Installation Guide

22
Installation
ABS Cellular Core Schedule 40 DWV Pipe & ABS DWV Fittings
For Non-Pressure Applications
>> Cure Times
Minimum Cure Time to Test
Cure times shown are sufficient to complete
a hydrostatic test at 4.3 PSI with 60%
humidity and cold water. Full cure may take
significantly longer.
Cure times are a function of air temperature,
water temperature, humidity and pipe size.
Increase the cure time for more demanding
conditions. For more specific information,
contact the cement manufacturer.
>> Special Considerations
Do NOT air test.
Teflon
®
tape should be used for 1-inch
or smaller and paste-type, non-hardening
thread sealant on 1
1
/
4
inch or larger.
UV sensitivity.
Do NOT install permanently in direct
sunlight without painting with water-based
latex paint, or covering with insulation.
Support every 4 feet.
Size 60˚- 100˚F 40˚- 60˚F - 40˚F
1
1
/
2
" to 3"
4" & 6"
2 Hours
6 Hours
4 Hours
12 Hours
16 Hours
48 Hours
ABS DWV Pipe & Fittings