How to Guide

30
Plastics Technical Manual
>> CPVC Copper Tube Size Pipe
NOTE: STRAIGHT LENGTH PIPE ARE SHIPPED IN FULL BUNDLE QUANTITY ONLY.
FlowGuard Gold
®
Pipe
NSF Listed. Meets All Requirements of ASTM D 2846.
STRAIGHT LENGTHS PLAIN END SDR 11 CPVC COPPER TUBE SIZE PIPE ASTM D 2846
TRUCKLOAD MAX WORK
PART NO. NOM. SIZE UPC # QTY. PER PERCENT QTY. PER AVG. OD (IN.) MIN. WALL PRESSURE WT. PER
611942- BUNDLE PER SKID SKID (IN.) AT 23° C OR 73° F 100 FT. (LBS.)
CTS 12005
1
2
w
Y       14* 
CTS 12005
1
2
w
Y       14* 
CTS 12007
3
4
w
Y       14* 
CTS 12007
3
4
w
Y       14* 
CTS 12010 1
w
Y       14* 
CTS 12010 1
w
Y       14* 
CTS 12012 1
1
4
w
Y       14* 
CTS 12012 1
1
4
w
Y       14* 
CTS 12015 1
1
2
w
Y       14* 
CTS 12015 1
1
2
w
Y       14* 
CTS 12020 2
w
Y       14* 
CTS 12020 2
w
Y       14* 
CTS 12005
1
2
w
Y       14* 
CTS 12007
3
4
w
Y       14* 
CTS 12010 1
w
Y       14* 
COILED PIPE SDR 11 COILED SDR CPVC COPPER TUBE SIZE PIPE ASTM D 2846
TRUCKLOAD MAX WORK
PART NO. NOM. SIZE UPC # QTY. PER PERCENT QTY. PER AVG. OD (IN.) MIN. WALL PRESSURE WT. PER
611942- BUNDLE PER SKID SKID (IN.) AT 23° C OR 73° F 100 FT. (LBS.)
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
 D;L;H j[ij m_j^ eh jhWdifehj%ijeh[
Yecfh[ii[ZW_heh]Wi_dFL9%78I%9FL9
f_f[eh\_jj_d]i$
D;L;Hj[ijFL9%78I%9FL9f_f[eh
\_jj_d]im_j^Yecfh[ii[ZW_heh]Wi"ehW_h
el[hmWj[hXeeij[hi$
EDBOki[FL9%78I%9FL9f_f[\ehmWj[h
ehWffhel[ZY^[c_YWbi$
 H[\[h je mWhd_d]i _d FF<7 Ki[h 8kbb[j_d
*#.&WdZ7IJC:'-.+$
PRODUCT DATA
NOTE: Please call Charlotte Pipe at 800/438-6091 or visit our
website www.CharlottePipe.com for the latest CPVC Chemical
Compatibility Sheet.