How to Guide

37
CPV 11005
1
2
x 19’ 13088 .840 .147 850 PSI 22.1
CPV 11007
3
4
x 19’ 13089 1.050 .154 690 PSI 30.0
CPV 11010 1
x 19’ 13090 1.315 .179 630 PSI 44.2
CPV 11012 1
1
4
x 19’ 13091 1.660 .191 520 PSI 61.0
CPV 11015 1
1
2
x 19’ 13092 1.900 .200 470 PSI 73.9
CPV 11020 2
x 19’ 13093 2.375 .218 400 PSI 102.2
CPV 11025 2
1
2
x 19’ 13094 2.875 .276 420 PSI 155.9
CPV 11030 3
x 19’ 13095 3.500 .300 370 PSI 208.6
CPV 11040 4
x 19’ 13096 4.500 .337 320 PSI 304.9
CPV 11060 6
x 19’ 13097 6.625 .432 280 PSI 581.5
CPV 11080 8
x 19’ 14138 8.625 .500 250 PSI 882.9
CPVC SCHEDULE 80 (LIGHT GRAY) PLAIN END CPVC 4120
MAX WORK
PART NO. NOM. SIZE UPC # AVG. OD (IN.) MIN. WALL (IN.) PRESSURE WT. PER
611942- AT 23° C OR 73° F 100 FT. (LBS.)
>> * CPVC Schedule 80 Pipe, Type IV, Grade 1
ASTM D 1784 & ASTM F 441
CPVC Schedule 80 Pipe
*
PRODUCT DATA
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFA’s website and
ASTM D 1785.
* Note: This product is not currently available for sale in the United States. Information provided is for reference only.
NSF Listed. Meets All Requirements of ASTM D 1784 and ASTM F 441.
Corzan is a registered trademark of Lubrizol Corp.