PVC 16012B 1
1
⁄
4
” x 20’ 04211 1.660 .064 160 PSI 2.75 21.5
PVC 16015B 1
1
⁄
2
” x 20’ 04210 1.900 .073 160 PSI 3.00 26.6
PVC 16020B 2” x 20’ 04212 2.375 .091 160 PSI 4.00 41.4
PVC 16025B 2
1
⁄
2
” x 20’ 12980 2.875 .110 160 PSI 4.00 61.4
PVC 16030B 3” x 20’ 04222 3.500 .135 160 PSI 4.00 90.8
PVC 16040B 4” x 20’ 12981 4.500 .173 160 PSI 4.00 149.8
PVC 16060B 6” x 20’ 12982 6.625 .255 160 PSI 4.00 325.0
PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665
PR 160 PVC 1120 BELL END ASTM D 2241 SDR 26
MAX WORK BELL
PART NO. NOM. SIZE UPC # AVG. OD MIN. WALL PRESSURE AT DEPTH WT. PER
611942- (IN.) (IN.) 23° C OR 73° F (IN.) 100 FT. (LBS.)
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
• NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
• Refer to warnings on PPFA’s website and
ASTM D 1785.
Pipe Data
PVC SDR Pipe