How to Guide

38
Plastics Technical Manual
NOT FOR PRESSURE
Do not use PVC Sewer pipe for pressure applications. The
use of sewer pipe in pressure applications may result in
system failure and property damage.
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFA’s website and
ASTM D 1785.
S/M 6004G 4
x 14’ 11920 840’ 5.556 14’-0
110.4 4.215 .120
S/M 6004G 4
x 20’ 04012 1200’ 7.144 20’-0
109.7 4.215 .120
S/M 6006G 6
x 14’ 11921 392’ 5.556 14’-0
249.6 6.275 .180
S/M 6006G 6
x 20’ 04016 560’ 8.330 20’-0
247.0 6.275 .180
S/M 6008G 8
x 14’ 11922 140’ 3.333 14’-0
451.0 8.400 .240
S/M 6004 4
x 10’ 04008 600’ 4.160 10’-0
108.3 4.215 .120
S/M 6004 4
x 20’ 04009 1200’ 7.144 20’-0
108.3 4.215 .120
S/M 6006 6
x 10’ 04013 280’ 4.160 10’-0
241.7 6.275 .180
S/M 6006 6
x 20’ 04014 560’ 8.330 20’-0
241.7 6.275 .180
>> PVC SDR 35 PSM Pipe
PVC Sewer Pipe
SDR-35 GASKETED - PS 46
TRUCKLOAD
PART NO. NOM. SIZE UPC # QTY. PER PERCENT LAYING WT. PER AVG. OD (IN.) MIN. WALL (IN.)
611942- SKID PER SKID LENGTH 100 FT. (LBS.)
ASTM D 3034 & ASTM F 477
SDR-35 SOLVENT WELD - PS 46
TRUCKLOAD
PART NO. NOM. SIZE UPC # QTY. PER PERCENT LAYING WT. PER AVG. OD (IN.) MIN. WALL (IN.)
611942- SKID PER SKID LENGTH 100 FT. (LBS.)
Weight is approximate and is for shipping purposes only.
Weight is approximate and is for shipping purposes only.
NOTE: For truckloads of mixed sizes, multiply skids desired by truckload percent per skid.
Meets All Requirements of ASTM D 3034.
SDR 35 Gaskets meet or exceed ASTM F 477.
Gasketed joints meet ASTM D 3212.
PRODUCT DATA