Dimensions Guide

26
Pipe Data
PVC 4005B**
1
2
x 10 04986 .840 .109 600 PSI 2.00 15.9
PVC 4005B**
1
2
x 20 03923 .840 .109 600 PSI 2.00 15.9
PVC 4007B**
3
4
x 10 04987 1.050 .113 480 PSI 2.25 21.1
PVC 4007B**
3
4
x 20 03926 1.050 .113 480 PSI 2.25 21.1
PVC 4010B** 1x 10 04988 1.315 .133 450 PSI 2.50 31.3
PVC 4010B** 1x 20 03929 1.315 .133 450 PSI 2.50 31.1
PVC 4012B
§
1
1
4
x 10 04989 1.660 .140 370 PSI 2.75 42.4
PVC 4012B
§
1
1
4
x 20 03930 1.660 .140 370 PSI 2.75 42.4
PVC 4015B
§
1
1
2
x 10 04990 1.900 .145 330 PSI 3.00 51.8
PVC 4015B
§
1
1
2
x 20 03931 1.900 .145 330 PSI 3.00 51.8
PVC 4020B
2x 10 04991 2.375 .154 280 PSI 4.00 69.5
PVC 4020B
2x 20 03932 2.375 .154 280 PSI 4.00 69.5
PVC 4025B
2
1
2
x 20 04206 2.875 .203 300 PSI 4.00 110.0
PVC 7300B
§
3x 10 04853 3.500 .216 260 PSI 4.00 147.6
PVC 4030B
3x 20 03933 3.500 .216 260 PSI 4.00 144.2
PVC 7400B
§
4x 10 04835 4.500 .237 220 PSI 4.00 212.3
PVC 9400B
4x 20 03964 4.500 .237 220 PSI 5.00 210.6
PVC 7600B
§
6x 10 04850 6.625 .280 180 PSI 6.50 379.3
PVC 9600B
6x 20 03965 6.625 .280 180 PSI 6.50 373.2
PVC 7800B
8x 10 09903 8.625 .322 160 PSI 7.00 556.9
PVC 9800B
8x 20 03967 8.625 .322 160 PSI 7.00 564.0
PVC 7910B
10x 20 03960 10.750 .365 140 PSI 9.00 781.4
PVC 7912B
12x 20 03962 12.750 .406 130 PSI 10.00 1033.2
PVC 7914B
14x 20 04863 14.000 .437 130 PSI 10.00 1221.8
PVC 7916B
16x 20 04929 16.000 .500 130 PSI 10.00 1594.5
M
A
D
E
I
N
U
.
S
.
A
.
PVC Schedule 40 Pipe - Bell End*
PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665
PVC SCHEDULE 40 (WHITE) BELL END PVC 1120 ASTM D 1785
MAX WORK
PART NO. NOM. SIZE UPC # AVG. OD MIN. WALL PRESSURE AT BELL DEPTH WT. PER
611942- (IN.) (IN.) 23° C OR 73° F (IN.) 100 FT. (LBS.)
* Bell dimensions meet either ASTM D 2672 or
ASTM F 480, depending upon pipe diameter
** ASTM D 1785
Dual Marked ASTM D 1785 & ASTM F 480
§ Dual Marked ASTM D 1785 & ASTM D 2665
Triple Marked ASTM D 1785 & ASTM D 2665 &
ASTM F 480
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
Refer to warnings on PPFA’s website and
ASTM D 1785.