How to Guide

27
PVC 4005
1
2
”
x10’ 06658 .840 .109 600PSI 15.9
PVC 4005
1
2
”
x20’ 03922 .840 .109 600PSI 15.9
PVC 4007
3
4
”
x10’ 06661 1.050 .113 480PSI 21.1
PVC 4007
3
4
”
x20’ 03925 1.050 .113 480PSI 21.1
PVC 4010 1
”
x10’ 06664 1.315 .133 450PSI 31.3
PVC 4010 1
”
x20’ 03928 1.315 .133 450PSI 31.3
PVC7100* 1
1
4
”
x10’ 03945 1.660 .140 370PSI 42.4
PVC7100* 1
1
4
”
x20’ 03946 1.660 .140 370PSI 42.4
PVC7112* 1
1
2
”
x10’ 03947 1.900 .145 330PSI 50.7
PVC7112* 1
1
2
”
x20’ 03948 1.900 .145 330PSI 50.7
PVC7200* 2
”
x10’ 03949 2.375 .154 280PSI 68.1
PVC7200* 2
”
x20’ 03950 2.375 .154 280PSI 68.1
PVC 4025‡ 2
1
2
”
x20’ 04205 2.875 .203 300PSI 108.0
PVC7300* 3
”
x10’ 03951 3.500 .216 260PSI 141.2
PVC7300* 3
”
x20’ 03952 3.500 .216 260PSI 141.2
PVC 7400 4
”
x10’ 03953 4.500 .237 220PSI 201.2
PVC 7400 4
”
x20’ 03954 4.500 .237 220PSI 201.2
PVC 7500 5
”
x20’ 04837 5.563 .258 190PSI 272.5
PVC 7600 6
”
x10’ 03955 6.625 .280 180PSI 353.7
PVC 7600 6
”
x20’ 03956 6.625 .280 180PSI 353.7
PVC 7800 8
”
x10’ 13087 8.625 .322 160PSI 532.3
PVC 7800 8
”
x20’ 03958 8.625 .322 160PSI 532.3
PVC 7910 10
”
x20’ 03959 10.750 .365 140PSI 754.7
PVC 7912 12
”
x20’ 03961 12.750 .406 130PSI 997.9
PVC 7914 14
”
x20’ 04862 14.000 .437 130PSI 1180.1
PVC 7916 16
”
x20’ 04918 16.000 .500 130PSI 1543.1
PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 1785
MAX WORK
PART NO. NOM. SIZE UPC # AVG. OD (IN.) MIN. WALL (IN.) PRESSURE WT. PER
611942- AT 23° C OR 73° F 100 FT. (LBS.)
>> PVC Schedule 40 Pipe - Plain End
PVC Pipe: Schedule 40
* Dual Marked ASTM D 1785 and ASTM D 2665.
† Triple Marked ASTM D 1785 & ASTM D 2665 & ASTM F 480.
‡ Dual Marked ASTM D 1785 & ASTM F 480.
NOTE: When ordering, please specify plain end or bell end.
NSF Listed. Meets All Requirements of ASTM D 1784 and ASTM D 1785.
PRODUCT DATA
Testing with or use of compressed air or gas in PVC / ABS
/ CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
• NEVER test with or transport/store
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe for water
or approved chemicals.
• Refer to warnings in PPFA User Bulletin
4-80 and ASTM D 1785.