Installation
STEP 4 AND 5 FOR CHAIN HUNG ONLY
FINAL ASSEMBLY
STEP 6:
INSTALLATION
IMPORTANT: DO NOT ATTACH FIXTURE DIREC
TLY TO OUTLET
BOX.
STEP 4:
Using 2 pairs of pliers, open one link of chain (S) and connect it to
the fixture loop (I) at the top of the fixture.
A. Take note of the color of the wire(s) on your fixture. Identify
which group your fixture wire(s) falls into and connect the wires
according to the directions below:
STEP 5:
STEP 6:
Lace wires up through chain (S) and pass wires through canopy
loop (E). We recommend lacing wire up through every other
link of chain (S).
*Note: When parallel wire is used, the tracer wire is square shaped
or ridged and less tracer wire is round in shape or smooth.
(Seen best when viewed from wire end.) To separate wires, grasp
the ends of each wire and pull apart.
C. Fit a wire connector (not supplied) over the wires and screw the
connector clockwise until you feel a firmness.
D. Try gently to pull the connector off the wires. If you can pull the
connector off, carefully re-do steps B and C, as above and check
again for a firm connection.
E. Connect the fixture wire from group B to the white wire from the
outlet box in the same manner.
GROUNDING INSTRUCTIONS: The green grounding screw (D) is
to be inserted into the hole with two raised dimples provided on the
mounting bar. Wrap the ground wire from the fixture (if supplied) and
the ground wire from the outlet box (bare metal or green
insulated wire) around the green grounding screw on the
mounting bar if uninsulated wire is on the mounting bar,
connect the ground wire from the fixture (if supplied) and the outlet
box to it using a small wire connector (not supplied).
NOTE: Underwriters Laboratories does not require all fixtures to
have ground wires. These fixtures still meet all UL specifications.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE
POWER SUPPLY WIRES.
GROUP A: CONNECT TO BLACK
HOUSE WIRE
BLACK
WHITE
*
PARALLEL WIRE (ROUND & SMOOTH)
*PARALLEL WIRE (SQUARE & RIDGED)
GROUP B: CONNECT TO WHITE
HOUSE WIRE
Raise glass shade (J) to ring (L) and secure with finial assembly (P).
Raise and attach loops (K) to arm hooks (M).
Install lamps.
CLEANING
To clean, wipe fixture with a soft cloth. Clean glass with a mild soap.
Do not use abrasive materials such as scouring pads or powders,
steel wool or abrasive paper.
STEP 2:
STEP 3:
Make sure no bare wires can be seen outside wire connectors.
STEP 1:
STEP 2:
STEP 3:
Insert fixture mounting screws (I) in threaded holes of offset
strap (C). Run screws all the way down to the heads.
Place flat strap (B) of mounting bar against outlet box (not supplied)
and fasten mounting bar, through slots in flat strap (B), to outlet box
with outlet box screws (K) (not supplied). Be sure the mounting
screws are perfectly horizontal so fixture hangs straight.
Hold mounting bar with flat strap (B) behind offset strap (C). Rotate
straps so they are at right angles to one another.
STEP 1:
After wires are connected, tuck them carefully inside outlet box and
then raise the canopy (H) against ceiling allowing for mounting
screws (I) to protrude through holes in canopy (H). Secure in place
with cap nuts (F).
B. Take your fixture wire(s) from group A and place evenly against
the black wire from the outlet box.
DO NOT twist wires together
before using wire connectors.