Installation Instructions
CAUTION RISK OF FIRE-
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
Outdoor
1A
13
GP I :ENERAL RODUCT NFORMATION
These fixtures are intended to be installed utilizing compliant junctionNEC
boxes.
This product is safety listed for wet locations.
Incandescent lamps may be dimmed with a standard incandescent dimmer.
LED LEDlamps may be dimmed with a dimmer. Consult lamp manufacturer
for additional information.
This instruction shows a typical installation.
Secure the mounting plate to the junction box.
1
2
3
4
5
6
7
8
9
10
LAMP
11
FIXTURE
SCREW
9
MOUNTING
PLATE
9
8
7
3
5
TOP COVER
JUNCTION BOX
12
12
GLASS CLIP
GLASS PANEL
COVER SCREW
FIXTURE LOOP
FIXTURE ARM
FIXTURE
BASE
LOWER COVER
7
8
9
10
1011
1012
1013
5
Outdoor Wall
Temporarily install the mounting plate to the junction box andmark the anchor hole locations through the mounting plate
holes. Remove the mounting plate.
Drill appropriate sized holes at the marked locations and installthe anchors.
Screw the anchor screws into the anchors.Attach the fixture arm to the fixture base and fixture loop
with the provided screws.
Slide glass panels into the lower cover and secure each panel with clips.
Connect the fixture to a suitable ground in accordance with local electrical codes.
Connect the white fixture wire to the neutral power line wire with a wire nut.
Connect the black fixture wire to the hot power line wire with a wire nut.
Mount the fixture base onto the mounting plate and secure it with the fixture screws.
Screw the lamps into the sockets. Refer to the label on the socket for Max Wattage Information.
Install the lower cover to the top cover by using the cover screws.
For wet locations, caulk around the base of the fixture with waterproof construction sealant.
Installation Instructions