® charnwood C-SERIES Operating & Installation Instructions
CONTENTS O P E R AT I N G I N S T R U C T I O N S Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Fitting The Riddling Grate . . . . . . . . . . . . . . 4 Lighting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Controlling The Fire . . . . . . . . . . . . . . . . . . . 5 Refuelling . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Ash Clearance . . . . . . . . . . . . . . . . . . . . . . . 5 Reduced Burning . . . . . . . . . . . . . . . . . . . . . 6 Maintenance . .
OPERATING INSTRUCTIONS ® Congratulations on becoming the owner of a HETAS approved These appliances have been approved by HETAS as intermittent Charnwood C-Series Stove. Your stove has been approved by DEFRA operating appliances for burning dry seasoned wood logs only. to burn wood logs in a smoke control area if it is used in accordance HETAS approval does not cover the use of other fuels either alone or with these instructions.
OPERATING INSTRUCTIONS ® CONTROLLING THE FIRE Fit the grate plates into position through the front and rear grate support plates, making sure they locate correctly onto the riddler The rate of burning and hence the output is controlled by the air rod. Fit the fuel retainer. Slide the ashpan under the grate. control (see Fig. 2). LIGHTING Open the air control fully (boost position) when lighting or when rapid burning is required.
OPERATING INSTRUCTIONS ® Fig.3. Throat Plate Position and Lowering To make ash removal easier there is a special Charnwood ash carrier Throat Plate available. This may be purchased from your supplier or, in case of difficulty, from Charnwood. REDUCED BURNING Pull Up and Swing Down For reduced burning the fire door must be closed.
OPERATING INSTRUCTIONS ® month of regular use after installation. when re-fuelling the stove. The chimney should be swept at least twice a year. Where the top c) When re-fuelling keep the fuel as far back from the front fence as outlet or vertical rear flue connector is used it will generally be possible, do not try to fit too much fuel into the firebox. possible to sweep the chimney through the appliance. d) Do not completely close the air control.
OPERATING INSTRUCTIONS ® and tightly close the door of the appliance. This should cause the chimney fire to go out in which case the controls should be kept closed until the stove has gone out. The chimney and flueways should then be cleaned. If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately. After a chimney fire the chimney should be carefully examined for any damage. Expert advice should be sought if necessary.
INSTALLATION INSTRUCTIONS ® HEALTH AND SAFET Y PRECAUTIONS SPECIFICATION Please take care when installing the stove that the requirements of Specification C-Four the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to C-Five C-Six C-Seven C-Eight Nominal Heat 5.0 6.7 4.9 Output 7.6 8.3 kW (BTU/hr) (16,700) (17,000) (22,800) (25,900) (28,300) come into contact with the skin. In case of contact wash with plenty of water.
INSTALLATION INSTRUCTIONS ® If there is no existing chimney then a prefabricated block chimney or a twin walled insulated stainless steel flue to BSEN 15287-1:2007 can be used either internally or externally. These chimneys must be fitted Fig. 4. Vertical Register Plate With Bricked Up Fireplace in accordance with the manufacturers instructions and Building Regulations.
INSTALLATION INSTRUCTIONS ® Fig. 7. Horizontal Register Plate With Optional Vertical Rear Flue Connector Fig. 8. Flue Blanking Plate. Back of Stove Blanking Plate Alternative Soot Door Positions Clamping Plate M8 Nut Glass Fibre Webbing Blanking Plate Register Plate With Soot Door Clamping plate finishes flush with inside face of firebox top and bottom.
INSTALLATION INSTRUCTIONS ® State or Minister in the devolved administrations. using a 10mm spanner. The pallet brackets can now be removed from the stove by tilting it and using a 13mm spanner to remove the bolts. The Charnwood C-FOUR, Charnwood C-FIVE, Charnwood C-SIX, These 4 bolts are required for levelling or fixing on the Store Stand. Charnwood C-SEVEN and Charnwood C-EIGHT have been The Stove may now be moved to its final position.
12 A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 CE Certificate for compliance with EN13240:2001 and UK HETAS requirements.
C-FOUR DIMENSIONS (mm) ® 82 114 154 131 373 405 Plan View 140 i/d to suit 125mm (5") flue pipe Optional Vertical Rear Flue Adapter Standard Model 416 613 144 560 458 84 45 267 386 64 OD 61 ID 416 763 710 Store Stand 608 195 150 386 Front 262 Side 14 Rear
C-FIVE DIMENSIONS (mm) ® 82 114 153 130 430 398 Plan View 140 i/d to suit 125mm (5") flue pipe Optional Vertical Rear Flue Adapter 485 Standard Model 611 144 560 458 65 292 455 79 76 Store Stand 485 796 745 643 250 185 455 Front 292 Side 15 Rear
C-SIX DIMENSIONS (mm) ® 88 131 169 146 441 398 Plan View Standard Model 441 670 156 i/d to suit 150mm (6") flue pipe Optional Vertical Rear Flue Adapter 161 615 505 119 411 63 292 79 To suit 80mm ducting Store Stand 441 855 690 800 185 411 Front 292 Side 16 Rear
C-SEVEN DIMENSIONS (mm) ® 85 130 169 146 440 398 Optional Vertical Rear Flue Adapter 156 i/d to suit 150mm (6") flue pipe Standard Model 564 160 670 615 505 292 534 59 76 79 OD Store Stand 564 855 800 690 244 185 529 292 Front Side 17 Rear
C-EIGHT DIMENSIONS (mm) ® 88 133 169 146 398 443 500 Optional Vertical Rear Flue Adapter 156 i/d to suit 150mm (6") flue pipe 163.
C-FOUR PARTS LIST ® Issue G 67 43 44 45 10 31 35 5 33 29 13 38 21 14 22 Optional Grate Kit 38 42 34 41 39 15 49 53 51 54 19 65 68 32 46 8 47 6 9 3 17 50 52 59 1 58 12 23 48 62 24 20 27 16 2 60 18 57 40 Item 1# 2 3 4 5 6 7 8 9 10# 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 25 36 Part No.
C-FIVE PARTS LIST ® Issue B 21 42 43 22 45 67 44 63 10 14 41 13 35 7 38 70 68 32 Optional Grate Kit 49 65 33 53 31 54 19 47 64 62 51 8 17 2 52 29 46 28 9 6 48 50 59 12 58 23 60 71 27 24 57 20 39 16 69 37 18 40 11 26 5 3 Item Part No.
C-SIX PARTS LIST ® Issue G 68 63 45 44 41 7 8 5 35 15 3 13 1 43 Optional Grate Kit 21 49 53 14 42 54 29 64 34 38 52 17 22 51 62 10 46 19 65 47 6 8 62 50 48 2 28 60 DETAIL A 12 32 9 39 27 18 3 16 57 32 25 18 40 26 36 59 23 24 20 58 37 9 11 66 30 4 Item Part No. Description Item Part No.
C-SEVEN PARTS LIST ® Issue A 21 42 68 43 70 44 45 67 63 10 7 22 13 14 35 38 Optional Grate Kit 33 38 32 49 38 19 29 47 53 38 54 41 64 65 33 62 8 6 28 31 9 57 59 12 58 27 71 4 23 30 24 66 17 51 52 48 50 60 20 39 16 36 18 40 37 69 25 11 26 5 3 1 46 2 Item Part Number Description Item Part No.
C-EIGHT PARTS LIST ® Issue A 7 43 38 31 33 29 35 13 15 38 14 Optional Grate Kit 49 45 53 65 67 54 43 5 21 3 17 68 34 52 62 42 51 46 66 6 10 41 55 22 50 48 1 47 62 39 32 2 16 6 19 60 12 18 57 40 36 25 37 25 8 58 23 24 20 9 59 11 28 26 64 63 30 4 27 Item Part No. Description Item Part No.
REV.C-Series v3 04.13 your premier dealer charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T: + 4 4 ( 0 ) 19 8 3 5 3 7 7 7 7 • F : + 4 4 ( 0 ) 19 8 3 5 3 7 7 8 8 • C O N TA C T U S AT W W W. C H A R N W O O D . C O M ® A D i v i s i o n o f A . J . We l l s & S o n s L i m i t e d Re g i s t e r e d i n E n g l a n d N o .