Operation Manual
HEALTHANDSAFET YPRECAUTIONS
Pleasetakecarewheninstallingthestovethattherequirementsof
theHealthandSafetyatWorkAct1974aremet.
Sometypesoffirecementarecausticandshouldnotbeallowedto
comeintocontactwiththeskin.Incaseofcontactwashwithplenty
ofwater.
Ifthereisapossibilityofdisturbinganyasbestosinthecourseof
installationthenpleaseuseappropriateprotectiveequipment.
Theremustnotbeanextractorfanfittedinthesameroomasthe
stoveasthiscancausetheappliancetoemitfumesintotheroom.
.
Minimiumareasaregiveninthefollowingtable:
Thisstoveiscapableofintermittentoperation,andisnotsuitablefor
useinasharedfluesystem.
InadditiontotheseinstructionstherequirementsofBS.8303and
BSEN15287-1:2007mustbefulfilled.LocalAuthorityBylawsand
BuildingRegulations,includingthosereferringtonationaland
EuropeanStandards,regardingtheinstallationofSolidFuelburning
appliances,fluesandchimneysmustalsobeobserved.
Buildingregulationsrequirethatwheneveraneworreplacement
fixedsolidfuelorwood/biomassapplianceisinstalledinadwellinga
carbonmonoxidealarmmustbefittedinthesameroomasthe
appliance.Furtherguidanceontheinstallationofthecarbon
monoxidealarmisavailableinBSEN50292:2002andfromthe
alarmmanufacturer'sinstructions.Provisionofanalarmmustnotbe
consideredasubstituteforeitherinstallingtheappliancecorrectlyor
ensuringregularservicingandmaintenanceoftheapplianceand
chimneysystem.
COALARMS
Theremustbeanadequateairsupplyintotheroominwhichthe
applianceisinstalledtoprovidecombustionair.Thecombustionair
supplymustbeviaapermanentlyopenvent.Therequirementfor
minimumfreeareaispartlydependentonthedesignairpermeability
ofthehouse.Inolderpropertiestheairpermeabilitywillbeabove
5.0m /(h.m ),butinsomemodernpropertiesitmaybeless.
3 2
The
ventmustbepositionedsuchthatitisnotliabletoblockage
SPECIFICATION
CHIMNEY
Theoutputsinthetablearebasedona45minutere-fuellingcycle
burningseasonedhardwoodlogs.Alltestsarecarriedoutin
accordancewithBSEN13240.
Inorderfortheappliancetoperformsatisfactorilythechimney
heightmustnotbelessthan4metresmeasuredverticallyfromthe
outletofthestovetothetopofthechimney.Theinternaldimensions
ofthechimneyshouldpreferablybe175mm(7")or200mm(8")
eithersquareorroundandMUSTNOTBELESSTHAN125mm
(5")forC-FourandC-Fiveor150mm(6")forC-Six,C-SevenandC-
Eight.
Ifanexistingchimneyistobeuseditmustbesweptandchecked,it
mustbeingoodcondition,freefromcracksandblockages,and
shouldnothaveanexcessivecrosssectionalarea.Ifitwaspreviously
usedby anopenfirethenthechimneyshouldbesweptonemonth
afterinstallationtoclearanysootfallswhichmayhaveoccurreddue
tothedifferenceincombustionbetweenthestoveandtheopenfire.
Ifyoufindthatthechimneyisinpoorconditionthenexpertadvice
shouldbesoughtregardingthenecessityofhavingthechimneylined.
Ifitisfoundnecessarytolinethechimneythenaliningsuitablefor
SolidFuelmustbeused.
9
®
INSTALLATIONINSTRUCTIONS
Specification
C-Four
C-Five
C-Six
C-Seven
C-Eight
NominalHeat
Output
kW(BTU/hr)
4.9
(16,700)
5.0
(17,000)
6.7
(22,800)
7.6
(25,900)
8.3
(28,300)
StoveWeight
kg
(Packed)
83
96
96
115
119
Flue
Temperature
°C
281
259
272
280
316
FluegasMass
Flowg/s
4.2
5.3
4.3
7.3
6.3
Hearth
Temperature
°C
51.6
69.9
88.1
55.4
53.4
Minimum
distancefrom
combustibles
mm
600side
600rear
500side
400rear
500side
500rear
500side
500rear
600side
650rear
Air
Permeability
m /(h.m )
3 2
MinimumVentArea cm (in )
2 2
C-Four
C-Five
C-Six
C-Seven
C-Eight
>5.0
No
Requirement
No
Requirement
9.4(1.5)
11(1.76)
16.5(2.6)
<5.0
27.5(4.3)
27.5(4.3)
36.9(5.7)
38.5(6.0)
44(6.8)