Charnwood Grosvenor Safety Information Important Information It is most important that both you, the customer and the installation engineer not only follow the instructions in this booklet, but that you are satisfied that the following conditions have been complied with. This stove must not be used with any solid fuel, it is only suitable for natural gas or liquefied petroleum gas (LPG) according to the burner unit supplied.
Charnwood Grosvenor Operating Instructions Please go through this section with the installation engineer so that you fully understand all the basic operating and maintenance procedures for your stove. a. Switching On/ Ignition. Depress the control knob and turn counter clockwise. Gas will flow to the pilot burner, the piezo igniter will give off a high voltage spark & the pilot burner will light. (More than one attempt may have to be made on first lighting the fire.
Should the stove burner cut out for any reason you should not try to re-light it for at least 5 minutes. If you are then unable to re-light the pilot as described earlier you should contact your stove supplier or engineer. To The Customer During normal operation, for example in the winter months when the stove will be in regular use, we advise that the pilot is left running continuously as this will allow for quick and easy lighting, while at the same time helping to prevent condensation.
the top of the burner unit. Ideally a vacuum cleaner should be used, but if not a soft brush will do. 2. Check the condition of the coals. Any damaged ones will affect the efficient operation of the stove and should be replaced with new ones available from your stove supplier. We hope these instructions have been clear and helpful and you are now able to enjoy the full benefit of your stove.
Charnwood Grosvenor Installation Instructions Notes to the Installation Engineer: Please make sure the customer is familiar with the initial lighting and operating procedures before leaving the site and that this instruction booklet is left with them when the final commissioning is complete. And Fire Opening Specification.
the stove and that the chimney is in good condition. If not, a chimney liner must be installed or a suitable class 2 gas flue used. An up-draught is necessary to ensure the products of combustion are fully evacuated. The stove must be installed in accordance with current gas and building regulations applicable. Connect and seal the stove flue collar to the chimney with a length of pipe fitting for a depth of at least 20mm (3/4").
Air Tunnel Air Tunnel 2 1 4 L 3 L Air Tunnel L 5 L L ø8.0 Holes 6 7 S 8 S 9 S 10 S S Fig. 3. Coal Layer 1 Natural Gas 11 12 L 1st Layer below shown dotted 15 18 L 13 L 16 L 19 17 L 20 L 14 L L Fig. 4.
11 12 L 6 7 L 13 L 8 L 14 L 9 L 15 L L 10 L L ø8.0 Holes 1 2 S 3 S 4 S 5 S Fig. 5. Coal Layer 1 LPG 1st Layer below, shown dotted 21 20 24 3rd Layer L 23 L 26 25 S 16 22 L L S 17 S 18 L L Fig. 6.