® charnwood ISLAND IIIB Operating & Installation Instructions
ISLAND IIIB CONTENTS O P E R AT I N G I N S T R U C T I O N S Fuel 4 Door Operation 4 Multi Grate 4 Lighting 4 Controlling The Fire 5 Riddling 5 Refuelling 5 Ash Clearance 5 Overnight Burning 6 Special Point when Burning Wood 6 Maintenance 6 Throat plate flueway cleaning 6 Chimney Sweeping 7 Trouble Shooting 7 If you need any Further Help 8 INSTALLATION INSTRUCTIONS Health & Safety Precautions 9 Specification 9 Chimney 9 Hearth & Fire Surround 9 Central Heating System
charnwood ISLAND OPERATING INSTRUCTIONS ® to close. The stove is normally run with the doors shut. Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out MULTI GRATE correctly and that the chimney has been swept, is sound and free Your Charnwood Island is fitted with a multi grate to enable wood to from any obstructions. The stove is not suitable for use in a shared be burned and ash to be cleared.
charnwood ISLAND OPERATING INSTRUCTIONS ® Fig. 2. Multifuel Grate just one control to be used. The balance between primary and secondary air for particular flue conditions is pre-set using the sliding ion it os nP control mounted on the thermostat box beneath the stove. Once set e Op this should not need to be adjusted. Riddle For correct firing we recommend the use of a stove pipe thermometer which may be purchased from your supplier or from ourselves.
charnwood ISLAND OPERATING INSTRUCTIONS ® OVERNIGHT BURNING running the fire at a fast rate for a few minutes. Do not use abrasive For overnight burning the fire doors must be closed. Use large logs cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure. Aerosol spray cleaners should rather than small ones. not be used near the appliance whilst it is under fire.
charnwood ISLAND OPERATING INSTRUCTIONS ® Fig. 4. Throat Plate b) chimneys and flueways are clear, c) a suitable fuel is being used, d) there is an adequate air supply into the room, e) an extractor fan is not fitted in the same room as the stove. f) there is sufficient draw in the chimney (once the chimney is warm a draught reading of at least 0.10 inches (2.5mm) water gauge (25 Pa) should be obtained). Lift throat plate at back, then pull forward and swing down.
charnwood ISLAND OPERATING INSTRUCTIONS ® a) Open doors and windows to ventilate the room. Chimney Fires b) Let the fire out and safely dispose of the fuel from the If the chimney is thoroughly and regularly swept, chimney fires should appliance. not occur. However, if a chimney fire does occur push the air control c) Check for flue or chimney blockage, and clean if required. in fully tightly close the doors of the appliance.
charnwood ISLAND INSTALLATION INSTRUCTIONS ® HEALTH AND SAFET Y PRECAUTIONS CHIMNEY Please take care when installing the stove that the requirements of In order for the appliance to perform satisfactorily, the chimney the Health and Safety at Work Act 1974 are met. height must not be less than 4 metres measured vertically from the outlet of the stove to the top of the chimney.
charnwood ISLAND INSTALLATION INSTRUCTIONS ® Fig. 5.
charnwood ISLAND INSTALLATION INSTRUCTIONS ® Fig. 8. Vertical Register Plate With Bricked Up Fireplace Fig. 11. Horizontal Register Plate With Optional Vertical Rear Flue Connector Soot Door In Side or Rear Of Chimney Alternative Soot Door Positions Register Plate Register Plate With Soot Door 197mm Fig. 9. Horizontal Register Plate With Rear Flue Connection the two screws provided.
charnwood ISLAND INSTALLATION INSTRUCTIONS ® 2. The plates round the sides and back of the grate must be in position and sitting correctly. Fig. 12. Flue Blanking Plate. Blanking Plate Back of the Stove Fig. 13. Thermostat Setting Thermostat Arm Seal Blanking Plate with fire cement Clamping Plate with fold horizontal Locking Nut 3 The throat plate must be fitted in the roof of the appliance and Thermostat Flap should be checked to ensure that it has not become dislodged in transit.
charnwood ISLAND ISLAND IIIB DIMENSIONS ® 196 Flue Outlet To Suit 175mm (7”) Flue Pipe 185 754 830 133 488 780 726 603 458 95 714 738 13
charnwood ISLAND ISLAND IIIB PARTS LIST ® Issue F 45 49 36 15 36 41 48 47 16 46 13 50 17 44 3 4 20 6 7 23 35 18 31 30 10 8 39 43 34 24 40 33 5 21 19 22 37 12 29 Item 1* 2* 3 4 5 6 7 8 9* 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Part No.
A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 EN13240:2001 ISLAND ROOMHEATERS & BOILER FIRED BY WOOD FUEL EC certificate of conformity no: DS50-CPD-2007 Maximum operating pressure: 1.5 bar Minimum distance to combustible materials Side: Rear: 200mm 120mm Emission of CO in flue gases: 0.67% Flue gas temperature: 354°C Space heating output: 9.0kW Water heating output: 9.
REV. ISLAND IIIB 06.13 Issue E your premier dealer charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T: + 4 4 ( 0 ) 19 8 3 5 3 7 7 7 7 • F : + 4 4 ( 0 ) 19 8 3 5 3 7 7 8 8 • C O N TA C T U S AT W W W. C H A R N W O O D . C O M ® A D i v i s i o n o f A . J . We l l s & S o n s L i m i t e d Re g i s t e r e d i n E n g l a n d N o .