CHARNWOOD LA30iB Operating and Installation Instructions Contents Operating Instructions General Points ...................................................3 Fuels ...................................................................3 Door Operation..................................................3 Lighting..............................................................3 Controlling The Fire .........................................3 Running The Fire With The Doors Open .......4 Heating System.................
OPERATING INSTRUCTIONS FOR THE CHARNWOOD LA30iB GENERAL POINTS Before lighting the fire check with the installer that the work and checks described in the installation instructions have been carried out correctly and that the chimney has been swept, is sound, and free from any obstructions. WARNING There must not be an extractor fan fitted in the same room as this appliance as this can cause the appliance to emit smoke and fumes into the room.
anthracite, or homefire which should be burnt with the secondary air inlet open. RUNNING THE FIRE WITH THE DOORS OPEN The fire may be run with the doors open. This will result in a reduction in efficiency and hence heat output, particularly to the boiler. The more reactive fuels, like homefire, will burn better when the doors are open than fuels like phurnacite, sunbrite and ancit.
brightly before filling with fuel. If the central heating pump is off overnight then the thermostat may be left at the same setting for both day and night operation. If the central heating pump is on overnight then set the thermostat control to give the required level of heating. Some experimentation may be necessary to find the setting most suitable for the particular fuel used and the draw on the chimney. For overnight burning the fire doors must be closed.
TROUBLE SHOOTING Fire Will Not Burn. Check that: a) the air inlet is not obstructed in any way, b) chimneys and flueways are clear, c) a suitable fuel is being used, d) there is an adequate air supply into the room, e) an extractor fan is not fitted in the same room as the fire. Fire Blazing Out Of Control.
INSTALLATION INSTRUCTIONS FOR THE CHARNWOOD LA30iB HEALTH AND SAFETY PRECAUTIONS Please take care when installing the appliance that the requirements of the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash with plenty of water. If there is a possibility of disturbing any asbestos in the course of installation then please use appropriate protective equipment.
breast, one in the front to give access for infilling and fixing the flue pipe, and one in the side to give access for the pipework. work in conjunction with the thermostat on the appliance and the minimum return thermostat. CENTRAL HEATING SYSTEM The central heating system must comply with BS:5449 part 1. If the system is to be a combined heating and domestic hot water system then a double feed indirect hot water storage cylinder to BS:1566 part 1 should be used.
22mm Open Vents Feed and Expansion Tank Cold Water Tank Overflow Overflow Domestic Hot Water Draw Off with the centre-line of the chimney, and must also extend to the point where the chimney narrows to its final size. Any large voids must be filled and flaunched to the flue pipe to ensure that all soot deposits can be cleared when the appliance is swept. Ensure that the flue pipe is not obstructed or restricted in any way and that all joints are well sealed.
ASSEMBLY back of the grate must be in position and sitting correctly. Fit the side panels, hood and top grid onto the appliance. Instructions for this are enclosed with the panel pack. 3. The throat plate must be fitted in the roof of the appliance. 18mm Replace any internal parts previously removed. PRE LIGHTING CHECK Before initial lighting check the following points: 1. The bottom grate bars must all be fitted and should move freely and easily when the riddling mechanism is operated. 2.
394 154 i/d 235 Boiler tappings are 1" B.S.P. female. Two each side. FLUE C L 150° 619 547506 405 265 200 235 59 554 120 164 Charnwood LA30iB Overall Dimensions (Dimensions are in mm) Page 11 LA30iB 3.
Issue G CHARNWOOD LA30iB PARTS LIST 48 47 49 41 32 34 18 31 38 45 46 Freestanding Kit 40 37 33a 20 27 19 21 26 12 17 16 7 5 36 33 42 30 15 39 14 13 28 29 23 Item Part No. 19 25 Description 24 24 9 8 35 Item Part No. 11 Nuts, bolts, screws and clips are not shown for clarity. To obtain spare parts contact your local stockist giving model, part no. and description. In case of difficulty contact the manufacturer at the address shown below.