User Manual
TABLE OF CONTENTS 1. Before You Begin .......................................................................................................... 3 What Is Included ............................................................................................................................... 3 Unpacking Instructions ..................................................................................................................... 3 Claims ....................................................................
1. BEFORE YOU BEGIN What Is Included • • • CORE™ 3x3 5 mm Allen Key Hanging Bracket with Mounting Hardware • • • Power Cord Warranty Card Quick Reference Guide Unpacking Instructions Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition. Claims If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not CHAUVET®.
Product at a Glance Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave Safety Notes Auto Programs Auto-ranging Power Supply Replaceable Fuse User-Serviceable P P P x These notes include important information about the mounting, usage, and maintenance of this product; read before using the product. • • • • • • • • • • • • • • • • • • • • Page 4 of 24 x x P P P Always connect the product to a grounded circuit to avoid the risk of electrocution.
2. INTRODUCTION Overview Microphone Display and Control Buttons DMX Out Fuse Holder DMX In Power In Power Out Back Panel View CORE™ 3x3 User Manual Rev.
Dimensions 13.6 in 344 mm 13.6 in 344 mm 6.2 in 156 mm Page 6 of 24 CORE™ 3x3 User Manual Rev.
3. SETUP AC Power The CORE™ 3x3 has an auto-ranging power supply and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Power Linking Power Linking Diagram The product provides power linking via the Edison/IEC outlet located in the back of the unit. st 1 Product nd 2 Product rd 3 Product Additional Products You can power link up to 3 CORE™ 3x3 units on 120 VAC or up to 7 CORE™ 3x3 units on 230 VAC.
Mounting Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. Orientation The CORE™ 3x3 may be mounted in any position; however, make sure adequate ventilation is provided around the product. Rigging • Before deciding on a location, always make sure there is easy access to the product for maintenance and programming.
Coffin Locks The CORE™ 3x3 may be attached to another CORE™ 3x3 by using their coffin locks. The coffin locks are for product alignment only and are not weight bearing. DO NOT hang product using only the coffin locks. 1. Place one CORE™ 3x3 next to the other, making sure to align the coffin lock’s male connector opening to the other product’s female connector opening. 2. Use the 5 mm Allen key to operate the locking mechanism. Once locked, the coffin lock hooks hold the CORE™ 3x3 units together.
4. OPERATION Control Panel Operation To access the control panel functions, use the four buttons located underneath the display.
Configuration (DMX) Starting Address Set the product in DMX mode to control with a DMX controller. 1. Connect the product to a suitable power outlet. 2. Turn the product on. 3. Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product. When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses. If you choose a starting address that is too high, you could restrict the access to some of the product’s channels.
DMX Channel Modes, Assignments, and Values 31-Channel Channel Function Value Setting 1 2 3 Red Green Blue 000 ó 255 0–100% 000 ó 255 0–100% 000 ó 255 0–100% Section 1 4 5 6 Red Green Blue 000 ó 255 0–100% 000 ó 255 0–100% 000 ó 255 0–100% Section 2 7 Red 000 ó 255 0–100% 8 Green 000 ó 255 0–100% 9 Blue 000 ó 255 0–100% 10 Red 000 ó 255 0–100% 11 Green 000 ó 255 0–100% 12 Blue 000 ó 255 0–100% 13 Red 000 ó 255 0–100% 14 15 Green Blue 000 ó 255 0–100% 000 ó 255 0–100% 16
DMX Channel Modes, Assignments, and Values (cont.
DMX Channel Modes, Assignments, and Values (cont.
DMX Channel Modes, Assignments, and Values (cont.) 5-Channel 3-Channel Channel Dimmer Red Green Blue 5 Shutter Channel 1 2 3 Page 16 of 24 Function 1 2 3 4 Function Red Green Blue Value 000 ó 255 000 ó 255 000 ó 255 000 ó 255 000 ó 010 Setting 0–100% 0–100% 0–100% 0–100% No function 011 ó 255 Strobe (slow to fast) Value Setting 000 ó 255 0–100% 000 ó 255 0–100% 000 ó 255 0–100% CORE™ 3x3 User Manual Rev.
Configuration (Standalone) Set the product in one of the standalone modes to control without a DMX controller. 1. Connect the product to power. 2. Turn the product on. Never connect a product that is operating in any standalone mode (either Static, Automatic, or Sound) to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.
Static Colors To select a static color, do the following: 1. Press
Master/Slave Mode The Master/Slave mode allows a single CORE™ 3x3 unit (the master) to control the actions of one or more CORE™ 3x3 units (the slaves) without the need of a DMX controller. The master unit will be set to operate in Master mode 1 (and in either an Auto program or Sound-Active mode), while the slave units will be set to operate in Slave mode 1. Once set and connected, the slave units will operate in unison with the master unit, each slave duplicating the master exactly.
Two-by-Two (2 x 2) Master/Slave Mode The Two-by-Two (2 x 2) Master/Slave mode allows a single CORE™ 3x3 unit (the master) to control the actions of 3 other CORE™ 3x3 units (the slaves) as if they were one unit, when positioned 2 units across by 2 units down. The master unit will be set to operate in Master mode 4 (and in either an Auto program or Sound-Active mode), while the slave units will be set to operate in Slave modes 2 through 4. Once set and connected, the four units will operate as one.
5. TECHNICAL INFORMATION Product Maintenance Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and mechanical wear. To maintain optimum performance and minimize wear, clean the product at least twice a month. However, usage and environmental conditions contribute to increased cleaning frequency. To clean the product, follow the instructions below. 1. Unplug the product from power. 2. Wait until the product is at room temperature.
6. TECHNICAL SPECIFICATIONS Dimensions and Weight Length Width Height Weight 6.2 in (156 mm) 13.6 in (344 mm) 13.6 in (344 mm) 13.6 lb (6.2 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Power Light Source Photo Optic Thermal DMX Ordering Page 22 of 24 Power Supply Type Range Voltage Selection Switching (internal) 100 to 240 V, 50/60 Hz Auto-ranging Parameter 120 V, 60 Hz 230 V, 50 Hz Consumption 226 W 226 W Operating current 1.9 A 0.
RETURNS To return a product or request support: • In the U.S., contact CHAUVET® World Headquarters (see Contact Us). • In the UK or Ireland, contact CHAUVET® Europe Ltd. (see Contact Us). • In Mexico, contact CHAUVET® Mexico (see Contact Us). In any other country, DO NOT contact CHAUVET®. Contact your distributor. www.chauvetlighting.com for distributors outside the U.S., United Kingdom, Ireland, or Mexico. See If you live outside the U.S.
CONTACT US WORLD HEADQUARTERS - CHAUVET® General Information Address: 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560 Toll free: (800) 762-1084 Technical Support Voice: (954) 577-4455 (Press 4) Fax: (954) 756-8015 Email: tech@chauvetlighting.com World Wide Web www.chauvetlighting.com UNITED KINGDOM AND IRELAND - CHAUVET® Europe Ltd.