MAINTENANCE AND STORAGE
5. MAINTENANCE AND STORAGE
Fog Machine Maintenance
Do not allow the fog machine to become clogged. After every 40 hours of continuous operation, use
CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter
in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fog fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-ventilated area until the tank is almost empty. Do not allow the pump to run
dry.
6. Refill with fog fluid to continue using the fog machine. Run the machine briefly to clear any
remaining cleaning solution from the pump and heater.
Storage
Before storing the fog machine, run FCQ through the system as described in the cleaning procedure
above; however, only follow steps 1 through 5. Do not refill the tank with fog fluid if storing the hazer.
Cleaning the system prior to storage will help prevent any particles from condensing inside the pump or
heater while not in use.
Do Not operate the machine without fluid at any time.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your
Geyser T6. Make sure you use FCQ regularly, no longer than 90 days between
cleanings, to increase the life of your product.
Test-run your Geyser T6 on a monthly basis to achieve the best performance.